← tous les HP

Zeuz 10500X

10" · 4 Ω · 500 W · 94.5 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance4 Ω
Fs48.4 Hz
Qts0.445
Qes0.467
Qms9.292
Vas34.6 L
Sd340 cm²
Xmax4.3 mm
Re3.81 Ω
Bl11.2 T·m
Mms50.6 g
Pe500 W
Sensibilité94.5 dB

Indication d'alignement

EBP104 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 22.7 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Monacor SPA-10PA54 +5.60.445 =37 +2.44 -0.393.5 -1close8 Ω vs 4 Ω: amp load changes · 150 W vs 500 W: lower power handling · Xmax 4 mm < 4.3 mm: lower excursion-limited SPL+
PHL Audio 3002 v201048.6 +0.20.436 -0.0129 -5.64 -0.392.3 -2.2close8 Ω vs 4 Ω: amp load changes · 200 W vs 500 W: lower power handling · Xmax 4 mm < 4.3 mm: lower excursion-limited SPL+
SICA PL10B25S57.6 +9.20.438 -0.0130.9 -3.74.8 +0.594.9 +0.4close8 Ω vs 4 Ω: amp load changes · 250 W vs 500 W: lower power handling+
Oberton 10B10044 -4.40.447 =40.5 +5.94.4 +0.192.5 -2close8 Ω vs 4 Ω: amp load changes · 100 W vs 500 W: lower power handling+
Jensen BS10N/25058 +9.60.438 -0.0130.9 -3.74.8 +0.595 +0.5close8 Ω vs 4 Ω: amp load changes · 250 W vs 500 W: lower power handling+
Jensen BS10N/250A58 +9.60.438 -0.0130.9 -3.74.8 +0.595 +0.5close8 Ω vs 4 Ω: amp load changes · 250 W vs 500 W: lower power handling+
Focal 27 H46.6 -1.80.499 +0.0530.4 -4.25 +0.793.7 -0.8close200 W vs 500 W: lower power handling+
Focal 10V 641250 +1.60.423 -0.0232.8 -1.83.3 -193.4 -1.1close8 Ω vs 4 Ω: amp load changes · 100 W vs 500 W: lower power handling · Xmax 3.3 mm < 4.3 mm: lower excursion-limited SPL+
Jensen SMOOTH BS 10N/250A58 +9.60.429 -0.0230.9 -3.74.7 +0.495.1 +0.6close8 Ω vs 4 Ω: amp load changes · 250 W vs 500 W: lower power handling+
Goldwood GW-10PC/443.1 -5.30.404 -0.0432.7 -1.94.8 +0.592.9 -1.6close200 W vs 500 W: lower power handling+

Comparer les 3 plus proches avec le 10500X →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.