Visaton W250 vp
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 55.6 Hz |
| Qts | 1.045 |
| Qes | 1.231 |
| Qms | 6.895 |
| Vas | 58.1 L |
| Sd | 359.7 cm² |
| Xmax | 3.4 mm |
| Re | 6.66 Ω |
| Bl | 7 T·m |
| Mms | 25.6 g |
| Pe | 90 W |
| Sensibilité | 91.9 dB |
Indication d'alignement
| EBP | 45 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma HP10 | 61 +5.4 | 1.057 +0.01 | 51 -7.1 | 3.1 -0.3 | 92.1 +0.2 | close | Xmax 3.1 mm < 3.4 mm: lower excursion-limited SPL | + |
| Skytronic SP 1000 | 52 -3.6 | 1.064 +0.02 | 51.6 -6.5 | 6 +2.6 | 90.6 -1.3 | close | + | |
| Goldwood GW-210/4 | 41.8 -13.8 | 1.067 +0.02 | 64.2 +6.1 | 3.5 +0.1 | 90.7 -1.2 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Fenton PS10 vp2 | 59.9 +4.3 | 1.01 -0.03 | 41.2 -16.9 | 3.2 -0.2 | 90.4 -1.5 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 3.2 mm < 3.4 mm: lower excursion-limited SPL | + |
| Eltax MILLENIUM 500 GRAVE vp | 54.6 -1 | 0.95 -0.09 | 38 -20.1 | 4.4 +1 | 88.7 -3.2 | usable | + | |
| Fonestar FPW 250 | 55 -0.6 | 0.825 -0.22 | 38 -20.1 | 3.9 +0.5 | 90.6 -1.3 | usable | + | |
| Monacor SP-250PA v2017 | 48 -7.6 | 0.779 -0.27 | 72 +13.9 | 4.3 +0.9 | 91.7 -0.2 | usable | + | |
| Faital PRO 10FE200 v2014 | 55 -0.6 | 0.695 -0.35 | 53.4 -4.7 | 4.7 +1.3 | 94.1 +2.2 | usable | + | |
| Focal 10C 5401 | 56.5 +0.9 | 0.796 -0.25 | 43.1 -15 | 3.2 -0.2 | 94.6 +2.7 | usable | 4 Ω vs 8 Ω: amp load changes · 60 W vs 90 W: lower power handling · Xmax 3.2 mm < 3.4 mm: lower excursion-limited SPL | + |
| Hyper Phase BF10R | 45 -10.6 | 0.831 -0.21 | 78 +19.9 | 3.5 +0.1 | 90.8 -1.1 | usable | 60 W vs 90 W: lower power handling | + |
Comparer les 3 plus proches avec le W250 vp →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.