Visaton TD
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 31 Hz |
| Qts | 0.324 |
| Qes | 0.36 |
| Qms | 3.28 |
| Vas | 200 L |
| Sd | 510 cm² |
| Xmax | 7.3 mm |
| Re | 5.88 Ω |
| Bl | 12.4 T·m |
| Mms | 48.1 g |
| Pe | 150 W |
| Sensibilité | 95.5 dB |
Indication d'alignement
| EBP | 86 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 53.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Visaton TD1 | 30.3 -0.7 | 0.327 = | 200 = | 7.6 +0.3 | 95.3 -0.2 | close | + | |
| Westra SW-300-2808 | 30 -1 | 0.322 = | 209 +9 | 9.3 +2 | 94.7 -0.8 | close | + | |
| Cabasse 30M22 | 31.5 +0.5 | 0.315 -0.01 | 196.1 -3.9 | 8 +0.7 | 97.7 +2.2 | close | + | |
| Visaton WS33NG | 30 -1 | 0.308 -0.02 | 190 -10 | 8 +0.7 | 94.5 -1 | close | + | |
| Rockford Fosgate S1-124 | 28 -3 | 0.326 = | 186 -14 | 9.9 +2.6 | 96.2 +0.7 | close | 4 Ω vs 8 Ω: amp load changes | + |
| AE Speakers TD12S | 31.5 +0.5 | 0.336 +0.01 | 159.4 -40.6 | 7 -0.3 | 94.9 -0.6 | close | Xmax 7 mm < 7.3 mm: lower excursion-limited SPL | + |
| Davis 31TCA12 vp rc | 32.5 +1.5 | 0.314 -0.01 | 222 +22 | 6 -1.3 | 96.2 +0.7 | close | Xmax 6 mm < 7.3 mm: lower excursion-limited SPL | + |
| Davis 31TCA12 v2009 | 32.5 +1.5 | 0.31 -0.01 | 222 +22 | 6 -1.3 | 95.9 +0.4 | close | Xmax 6 mm < 7.3 mm: lower excursion-limited SPL | + |
| Samy Speaker LW1200 | 30.7 -0.3 | 0.36 +0.04 | 210 +10 | 6 -1.3 | 94.3 -1.2 | close | 100 W vs 150 W: lower power handling · Xmax 6 mm < 7.3 mm: lower excursion-limited SPL | + |
| Focal 12V 726DB | 25.9 -5.1 | 0.354 +0.03 | 210.5 +10.5 | 8.5 +1.2 | 96 +0.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le TD →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.