← tous les HP

TC Sounds TC2000 vp

15" · 4 Ω · 1000 W · 92.5 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance4 Ω
Fs18 Hz
Qts0.323
Qes0.35
Qms4.26
Vas267 L
Sd854 cm²
Xmax14 mm
Re3.19 Ω
Bl17.6 T·m
Mms299.4 g
Pe1000 W
Sensibilité92.5 dB

Indication d'alignement

EBP51 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 70.4 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Dayton Audio TS400D-4 TITANIC MK 417.1 -0.90.367 +0.04261 -618.8 +4.890.3 -2.2close+
Stereo Integrity HT 1518.5 +0.50.349 +0.03220 -4724.7 +10.791.1 -1.4usable+
Dayton Audio RSS390HF-418 =0.423 +0.1281.8 +14.814 =91.1 -1.4usable500 W vs 1000 W: lower power handling+
Rythmik Audio DS150117.5 -0.50.315 -0.01295 +287.5 -6.592.9 +0.4usable300 W vs 1000 W: lower power handling · Xmax 7.5 mm < 14 mm: lower excursion-limited SPL+
Dayton Audio ST385-818.8 +0.80.317 -0.01301 +347.9 -6.191.2 -1.3usable8 Ω vs 4 Ω: amp load changes · 300 W vs 1000 W: lower power handling · Xmax 7.9 mm < 14 mm: lower excursion-limited SPL+
Visaton TIW 400-823 +50.35 +0.03300 +3327 +1391.8 -0.7usable8 Ω vs 4 Ω: amp load changes · 300 W vs 1000 W: lower power handling+
Oxygen ALIUM 38018 =0.3 -0.02322 +557.9 -6.193.3 +0.8usable200 W vs 1000 W: lower power handling · Xmax 7.9 mm < 14 mm: lower excursion-limited SPL+
Visaton TIW40023 +50.348 +0.02300 +3310.6 -3.493.3 +0.8usable8 Ω vs 4 Ω: amp load changes · 300 W vs 1000 W: lower power handling · Xmax 10.6 mm < 14 mm: lower excursion-limited SPL+
Dayton Audio DCS385-417.5 -0.50.389 +0.07311 +449.3 -4.791.8 -0.7usable300 W vs 1000 W: lower power handling · Xmax 9.3 mm < 14 mm: lower excursion-limited SPL+
Dayton Audio RSS390HO-4 v201721.5 +3.50.32 =168 -9911.4 -2.692.7 +0.2usableXmax 11.4 mm < 14 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le TC2000 vp →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.