Supravox 245 HERITAGE EXC 06V
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 50.4 Hz |
| Qts | 0.44 |
| Qes | 0.506 |
| Qms | 3.37 |
| Vas | 100 L |
| Sd | 330 cm² |
| Xmax | 3.5 mm |
| Re | 6.5 Ω |
| Bl | 7.9 T·m |
| Mms | 15.2 g |
| Pe | 50 W |
| Sensibilité | 96.9 dB |
Indication d'alignement
| EBP | 100 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 63.2 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| P.Audio E10-150S | 53 +2.6 | 0.5 +0.06 | 84.09 -15.91 | 4.1 +0.6 | 95.4 -1.5 | usable | + | |
| Fane SOVEREIGN 10-125 | 50 -0.4 | 0.488 +0.05 | 80.2 -19.8 | 5 +1.5 | 95.3 -1.6 | usable | + | |
| Eminence ALPHA 10 v2 | 50.9 +0.5 | 0.505 +0.07 | 76.4 -23.6 | 3.2 -0.3 | 96.2 -0.7 | usable | Xmax 3.2 mm < 3.5 mm: lower excursion-limited SPL | + |
| Davis 25SCA10T | 41 -9.4 | 0.449 +0.01 | 91.3 -8.7 | 4.8 +1.3 | 93.4 -3.5 | usable | + | |
| Fostex 10W150 | 54.4 +4 | 0.394 -0.05 | 79.2 -20.8 | 3 -0.5 | 97.8 +0.9 | usable | Xmax 3 mm < 3.5 mm: lower excursion-limited SPL | + |
| Eminence BASSLITE SC10 | 46 -4.4 | 0.448 +0.01 | 78.3 -21.7 | 4.4 +0.9 | 91.5 -5.4 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Eminence BETA 10CX | 49 -1.4 | 0.397 -0.04 | 64.2 -35.8 | 5 +1.5 | 96 -0.9 | usable | + | |
| Supravox 215-2000EXC_08V | 49 -1.4 | 0.344 -0.1 | 97.8 -2.2 | 2.9 -0.6 | 100.1 +3.2 | usable | 20 W vs 50 W: lower power handling · Xmax 2.9 mm < 3.5 mm: lower excursion-limited SPL | + |
| Eminence ALPHA 10 | 50 -0.4 | 0.586 +0.15 | 82.2 -17.8 | 3.2 -0.3 | 95.7 -1.2 | usable | Xmax 3.2 mm < 3.5 mm: lower excursion-limited SPL | + |
| Eminence ALPHA 10 A | 50 -0.4 | 0.586 +0.15 | 82.2 -17.8 | 3.2 -0.3 | 95.7 -1.2 | usable | Xmax 3.2 mm < 3.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 245 HERITAGE EXC 06V →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.