STX W.25.300.8.MC
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 51 Hz |
| Qts | 0.483 |
| Qes | 0.58 |
| Qms | 2.9 |
| Vas | 59 L |
| Sd | 346 cm² |
| Xmax | 4 mm |
| Re | 5.2 Ω |
| Bl | 8.9 T·m |
| Mms | 27.7 g |
| Pe | 150 W |
| Sensibilité | 95.2 dB |
Indication d'alignement
| EBP | 88 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 51.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence BETA10 | 53 +2 | 0.489 +0.01 | 60.1 +1.1 | 5 +1 | 95.8 +0.6 | close | + | |
| Dayton Audio PA255-8 | 46.4 -4.6 | 0.484 = | 59 = | 5 +1 | 94.6 -0.6 | close | + | |
| Faital PRO 10FE200 | 55 +4 | 0.49 +0.01 | 61 +2 | 4.62 +0.62 | 96 +0.8 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Mercuriale PTR 256 M0 | 50 -1 | 0.498 +0.02 | 56.9 -2.1 | 3.5 -0.5 | 94.2 -1 | close | 100 W vs 150 W: lower power handling · Xmax 3.5 mm < 4 mm: lower excursion-limited SPL | + |
| Eminence BETA 10 A | 53 +2 | 0.489 +0.01 | 60.1 +1.1 | 3 -1 | 95.8 +0.6 | close | Xmax 3 mm < 4 mm: lower excursion-limited SPL | + |
| Ciare HX255 GR vp | 55.3 +4.3 | 0.569 +0.09 | 57.4 -1.6 | 4 = | 95.4 +0.2 | close | 100 W vs 150 W: lower power handling | + |
| Eminence BASSLITE CA2010 | 51 = | 0.505 +0.02 | 49 -10 | 3.5 -0.5 | 94.6 -0.6 | close | Xmax 3.5 mm < 4 mm: lower excursion-limited SPL | + |
| Fane SOVEREIGN 10-125 | 50 -1 | 0.488 +0.01 | 80.2 +21.2 | 5 +1 | 95.3 +0.1 | close | + | |
| Faital PRO 10FE300 | 50 -1 | 0.52 +0.04 | 50.5 -8.5 | 5.52 +1.52 | 96 +0.8 | close | + | |
| Eminence BETA-10A | 53 +2 | 0.49 +0.01 | 60.1 +1.1 | 3 -1 | 97 +1.8 | close | Xmax 3 mm < 4 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le W.25.300.8.MC →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.