Stereo Integrity SQL-15 15
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 23.8 Hz |
| Qts | 0.418 |
| Qes | 0.45 |
| Qms | 5.83 |
| Vas | 115 L |
| Sd | 800 cm² |
| Xmax | 12.1 mm |
| Re | 3.5 Ω |
| Bl | 20.1 T·m |
| Mms | 348.9 g |
| Pe | 1000 W |
| Sensibilité | 90.9 dB |
Indication d'alignement
| EBP | 53 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 61.8 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| TC Sounds LMS R15 | 23.6 -0.2 | 0.446 +0.03 | 123 +8 | 12.1 = | 90.2 -0.7 | close | + | |
| JL Audio 13W7AE-D1.5 | 23.5 -0.3 | 0.448 +0.03 | 104.3 -10.7 | 12.1 = | 91.7 +0.8 | close | 750 W vs 1000 W: lower power handling | + |
| Ground Zero GZHW 38X | 22.6 -1.2 | 0.43 +0.01 | 147 +32 | 12.5 +0.4 | 90.3 -0.6 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio RSS390HO-4 | 24.2 +0.4 | 0.384 -0.03 | 109.7 -5.3 | 9.6 -2.5 | 91.5 +0.6 | close | Xmax 9.6 mm < 12.1 mm: lower excursion-limited SPL | + |
| Dayton Audio MX15-22 | 21.7 -2.1 | 0.415 = | 146.1 +31.1 | 12.3 +0.2 | 90.1 -0.8 | close | + | |
| Ciare 15.00SW-4 | 29 +5.2 | 0.407 -0.01 | 113 -2 | 11.1 -1 | 93.4 +2.5 | close | Xmax 11.1 mm < 12.1 mm: lower excursion-limited SPL | + |
| Rockford Fosgate T0D215 | 25.5 +1.7 | 0.438 +0.02 | 94.4 -20.6 | 9.3 -2.8 | 90.9 = | usable | Xmax 9.3 mm < 12.1 mm: lower excursion-limited SPL | + |
| 18 Sound 15NTLS3500 | 28 +4.2 | 0.42 = | 141 +26 | 15.3 +3.2 | 89 -1.9 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio SS15-22 | 27 +3.2 | 0.388 -0.03 | 98 -17 | 10.3 -1.8 | 90.4 -0.5 | usable | 8 Ω vs 4 Ω: amp load changes · Xmax 10.3 mm < 12.1 mm: lower excursion-limited SPL | + |
| Dayton Audio TIT400C | 24.2 +0.4 | 0.483 +0.07 | 154.3 +39.3 | 13.3 +1.2 | 91.5 +0.6 | usable | + |
Comparer les 3 plus proches avec le SQL-15 15 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.