← tous les HP

Stereo Integrity HST-18 MKII

18" · 4 Ω · 2000 W · 90.4 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale18"
Impédance4 Ω
Fs15.6 Hz
Qts0.327
Qes0.35
Qms5
Vas307 L
Sd1178.4 cm²
Xmax19 mm
Re3.8 Ω
Bl26.5 T·m
Mms660 g
Pe2000 W
Sensibilité90.4 dB

Indication d'alignement

EBP45 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 83.5 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Stereo Integrity HST-18 MkIII14.8 -0.80.357 +0.03284 -2319 =89.5 -0.9close+
Stereo Integrity HST-18 Dual 2 Ohms16.4 +0.80.388 +0.06267 -4019 =89.7 -0.7close+
CSS Audio Maelstrom 18 DVC by Exodus Audio17.4 +1.80.376 +0.05313 +614.7 -4.391.2 +0.8usable1000 W vs 2000 W: lower power handling · Xmax 14.7 mm < 19 mm: lower excursion-limited SPL+
Stereo Integrity HT 1817 +1.40.383 +0.06411.9 +104.925.1 +6.192.5 +2.1usable+
TC Sounds LMS-ULTRA 540020.5 +4.90.325 =240.7 -66.316 -393.1 +2.7usableXmax 16 mm < 19 mm: lower excursion-limited SPL+
Dayton Audio RSS460HO-4 v201518.8 +3.20.322 -0.01272 -3511.9 -7.193.1 +2.7usable900 W vs 2000 W: lower power handling · Xmax 11.9 mm < 19 mm: lower excursion-limited SPL+
BMS 18N86225.1 +9.50.34 +0.01312 +519 =95 +4.6usable8 Ω vs 4 Ω: amp load changes · 1500 W vs 2000 W: lower power handling+
Dayton Audio RSS460HO-419.6 +40.387 +0.06298 -912.8 -6.292.9 +2.5usable900 W vs 2000 W: lower power handling · Xmax 12.8 mm < 19 mm: lower excursion-limited SPL+
BMS 18N86024 +8.40.372 +0.04304 -315 -493.7 +3.3usable8 Ω vs 4 Ω: amp load changes · 1500 W vs 2000 W: lower power handling · Xmax 15 mm < 19 mm: lower excursion-limited SPL+
Dayton Audio SS18-2221 +5.40.374 +0.05224 -8312.8 -6.290.6 +0.2usable8 Ω vs 4 Ω: amp load changes · 1300 W vs 2000 W: lower power handling · Xmax 12.8 mm < 19 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le HST-18 MKII →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.