← tous les HP

Sica 6 N 2.5 PL

6" · 8 Ω · 300 W · 92.5 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale6"
Impédance8 Ω
Fs80 Hz
Qts0.27
Qes0.29
Qms3.05
Vas4.9 L
Sd122.7 cm²
Xmax4.5 mm
Re6.2 Ω
Bl13.5 T·m
Mms17.1 g
Pe300 W
Sensibilité92.5 dB

Indication d'alignement

EBP276 · ported
Sealed Vb (Qtc ≈ 0.71)≈ 0.8 L

EBP > 100 : favorise un alignement bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Faital PRO 6FE400100 +200.36 +0.094.9 =4.87 +0.3793 +0.5usable4 Ω vs 8 Ω: amp load changes · 200 W vs 300 W: lower power handling+
LaVoce WSN061.52-490 +100.37 +0.15.15 +0.254 -0.592.5 =usable4 Ω vs 8 Ω: amp load changes · 125 W vs 300 W: lower power handling · Xmax 4 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6PR16090 +100.33 +0.065.9 +15 +0.595 +2.5usable120 W vs 300 W: lower power handling+
Faital PRO 6FE400100 +200.36 +0.095 +0.14.77 +0.2794 +1.5usable200 W vs 300 W: lower power handling+
LaVoce MAN062.00103 +230.3 +0.034.07 -0.833.9 -0.695 +2.5usableXmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6RS14065 -150.27 =9.3 +4.45.6 +1.193 +0.5usable200 W vs 300 W: lower power handling+
LaVoce WSF061.5291 +110.34 +0.076.62 +1.723.8 -0.795 +2.5usable125 W vs 300 W: lower power handling · Xmax 3.8 mm < 4.5 mm: lower excursion-limited SPL+
LaVoce WSN061.5290 +100.39 +0.125.92 +1.023.8 -0.794 +1.5usable125 W vs 300 W: lower power handling · Xmax 3.8 mm < 4.5 mm: lower excursion-limited SPL+
Faital PRO 6FE30098 +180.41 +0.144.4 -0.53.9 -0.692 -0.5usable4 Ω vs 8 Ω: amp load changes · 175 W vs 300 W: lower power handling · Xmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+
LaVoce MAN062.00-16103 +230.34 +0.073.77 -1.133.9 -0.694.5 +2usable16 Ω vs 8 Ω: amp load changes · Xmax 3.9 mm < 4.5 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 6 N 2.5 PL →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.