Paramètres Thiele-Small
| Taille nominale | 6" |
|---|---|
| Impédance | 8 Ω |
| Fs | 110 Hz |
| Qts | 0.46 |
| Qes | 0.55 |
| Qms | 2.65 |
| Vas | 4 L |
| Sd | 122.7 cm² |
| Xmax | 1.5 mm |
| Re | 5 Ω |
| Bl | 8.35 T·m |
| Mms | 11.2 g |
| Pe | 130 W |
| Sensibilité | 93.9 dB |
Indication d'alignement
| EBP | 200 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 2.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Faital PRO 6FE300 | 100 -10 | 0.46 = | 4.7 +0.7 | 3.9 +2.4 | 94 +0.1 | close | + | |
| LaVoce WSN061.52-16 | 108 -2 | 0.53 +0.07 | 4.46 +0.46 | 3.7 +2.2 | 93 -0.9 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 6FE200 | 120 +10 | 0.42 -0.04 | 4.3 +0.3 | 4.62 +3.12 | 95 +1.1 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Eminence ALPHA 6C | 107 -3 | 0.45 -0.01 | 5.7 +1.7 | 3.5 +2 | 93.3 -0.6 | usable | 4 Ω vs 8 Ω: amp load changes · 100 W vs 130 W: lower power handling | + |
| Faital PRO 6FE300 | 98 -12 | 0.41 -0.05 | 4.4 +0.4 | 3.9 +2.4 | 92 -1.9 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Faital PRO 6PR122 | 110 = | 0.39 -0.07 | 4.7 +0.7 | 2.75 +1.25 | 97 +3.1 | usable | + | |
| Sica 6 D 1.5 CS | 108.5 -1.5 | 0.63 +0.17 | 4.4 +0.4 | 1.5 = | 91.7 -2.2 | usable | 100 W vs 130 W: lower power handling | + |
| Eminence BETA-6A | 123 +13 | 0.56 +0.1 | 3.51 -0.49 | 4.5 +3 | 94 +0.1 | usable | + | |
| Faital PRO 6FE400 | 100 -10 | 0.5 +0.04 | 5.5 +1.5 | 4.77 +3.27 | 94 +0.1 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| LaVoce MAN062.00-16 | 103 -7 | 0.34 -0.12 | 3.77 -0.23 | 3.9 +2.4 | 94.5 +0.6 | usable | 16 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 6 D 1.5 SL →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.