Sica 15 PNS 4
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 37.3 Hz |
| Qts | 0.35 |
| Qes | 0.38 |
| Qms | 5.21 |
| Vas | 116.3 L |
| Sd | 855.3 cm² |
| Xmax | 9 mm |
| Re | 5.1 Ω |
| Bl | 22.73 T·m |
| Mms | 161.8 g |
| Pe | 1200 W |
| Sensibilité | 96 dB |
Indication d'alignement
| EBP | 98 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 37.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Peavey 15 LOW MAX | 38.2 +0.9 | 0.352 = | 125.6 +9.3 | 9.8 +0.8 | 96 = | close | + | |
| Peavey LO MAX 15 v2011 | 38.5 +1.2 | 0.352 = | 124 +7.7 | 9.2 +0.2 | 96.6 +0.6 | close | + | |
| BMS 15N850 | 37 -0.3 | 0.325 -0.02 | 111 -5.3 | 8.8 -0.2 | 95.7 -0.3 | close | Xmax 8.8 mm < 9 mm: lower excursion-limited SPL | + |
| BMS 15N850V2 v2015 | 37 -0.3 | 0.325 -0.02 | 111 -5.3 | 8.8 -0.2 | 95.7 -0.3 | close | Xmax 8.8 mm < 9 mm: lower excursion-limited SPL | + |
| B&C 15 SW 100 | 37 -0.3 | 0.318 -0.03 | 110 -6.3 | 9.5 +0.5 | 95.8 -0.2 | close | + | |
| Dayton Audio PA385S-8 | 37 -0.3 | 0.369 +0.02 | 111.5 -4.8 | 8.5 -0.5 | 95 -1 | close | Xmax 8.5 mm < 9 mm: lower excursion-limited SPL | + |
| BMS 15N850vv2 | 37 -0.3 | 0.33 -0.02 | 110.96 -5.34 | 12 +3 | 95 -1 | close | + | |
| Beyma 15LEX1000Fe | 41 +3.7 | 0.34 -0.01 | 116 -0.3 | 11 +2 | 97 +1 | close | + | |
| Faital PRO 15HP1010 | 40 +2.7 | 0.37 +0.02 | 107.5 -8.8 | 9.75 +0.75 | 96 = | close | 700 W vs 1200 W: lower power handling | + |
| Selenium 15SW1P | 40 +2.7 | 0.35 = | 120 +3.7 | 7.9 -1.1 | 96.9 +0.9 | close | 800 W vs 1200 W: lower power handling · Xmax 7.9 mm < 9 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 PNS 4 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.