SEAS 25F-WBC vp2 Gils
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 16 Ω |
| Fs | 35.1 Hz |
| Qts | 0.58 |
| Qes | 0.69 |
| Qms | 3.63 |
| Vas | 129.6 L |
| Sd | 330 cm² |
| Xmax | 4 mm |
| Re | 10 Ω |
| Bl | 8.8 T·m |
| Mms | 24.2 g |
| Pe | 60 W |
| Sensibilité | 90.1 dB |
Indication d'alignement
| EBP | 51 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 266.5 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| SEAS 25F-WBC vp1 Gils | 35.1 = | 0.58 = | 129.6 = | 6 +2 | 90.1 = | close | + | |
| Europsonic HP25/100 vp | 36.6 +1.5 | 0.552 -0.03 | 124.4 -5.2 | 5.5 +1.5 | 91.6 +1.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Cube F10 SELECT | 30 -5.1 | 0.567 -0.01 | 121 -8.6 | 4.6 +0.6 | 90.2 +0.1 | close | 8 Ω vs 16 Ω: amp load changes · 25 W vs 60 W: lower power handling | + |
| SEAS 25F-WBX | 32 -3.1 | 0.597 +0.02 | 114.5 -15.1 | 6 +2 | 89.9 -0.2 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Morel MW 1075 | 29 -6.1 | 0.622 +0.04 | 123 -6.6 | 4.3 +0.3 | 88.6 -1.5 | close | 8 Ω vs 16 Ω: amp load changes | + |
| Cube F10 NEO | 30 -5.1 | 0.505 -0.07 | 127 -2.6 | 5.1 +1.1 | 91.8 +1.7 | usable | 8 Ω vs 16 Ω: amp load changes · 30 W vs 60 W: lower power handling | + |
| Audax SON28A vp | 30 -5.1 | 0.505 -0.07 | 114.2 -15.4 | 4 = | 89.1 -1 | usable | 8 Ω vs 16 Ω: amp load changes · 30 W vs 60 W: lower power handling | + |
| Monacor SP-254TC | 30 -5.1 | 0.505 -0.07 | 109 -20.6 | 5 +1 | 90 -0.1 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Visaton W250 8 Ohms | 37 +1.9 | 0.781 +0.2 | 135 +5.4 | 5 +1 | 91 +0.9 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Morel MW 1077 | 28 -7.1 | 0.501 -0.08 | 147 +17.4 | 4.3 +0.3 | 89.9 -0.2 | usable | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 25F-WBC vp2 Gils →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.