← tous les HP

Scan-Speak 26W/4867T00

10" · 4 Ω · 170 W · 91.6 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance4 Ω
Fs18 Hz
Qts0.294
Qes0.31
Qms5.8
Vas223 L
Sd320 cm²
Xmax9 mm
Re3.7 Ω
Bl8.2 T·m
Mms50.3 g
Pe170 W
Sensibilité91.6 dB

Indication d'alignement

EBP58 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 46.6 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Scan-Speak 26W/8861T0019 +10.31 +0.02234 +119 =90 -1.6close8 Ω vs 4 Ω: amp load changes · 80 W vs 170 W: lower power handling+
Aurum Cantus AC250F120 +20.287 -0.01224 +18 -190 -1.6close8 Ω vs 4 Ω: amp load changes · Xmax 8 mm < 9 mm: lower excursion-limited SPL+
Scan-Speak 26W/8867T0019 +10.29 =179 -449 =89.4 -2.2close8 Ω vs 4 Ω: amp load changes+
Visaton WSP26S19 +10.34 +0.05230 +711 +290.2 -1.4close8 Ω vs 4 Ω: amp load changes · 110 W vs 170 W: lower power handling+
Scan-Speak 26W8867T0019 +10.29 =176 -479 =89.3 -2.3close8 Ω vs 4 Ω: amp load changes+
Scan-Speak 25W/8565-0119 +10.338 +0.04229 +66.5 -2.590 -1.6usable8 Ω vs 4 Ω: amp load changes · 100 W vs 170 W: lower power handling · Xmax 6.5 mm < 9 mm: lower excursion-limited SPL+
Accuton S280-6-28220 +20.263 -0.03226 +36 -390.9 -0.7usable8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 9 mm: lower excursion-limited SPL+
Aurum Cantus AC250/75C2C23 +50.275 -0.02193 -308 -191.2 -0.4usable8 Ω vs 4 Ω: amp load changes · Xmax 8 mm < 9 mm: lower excursion-limited SPL+
Monacor SPH-250CTC vp CARBON20 +20.247 -0.05220 -37.5 -1.594 +2.4usable100 W vs 170 W: lower power handling · Xmax 7.5 mm < 9 mm: lower excursion-limited SPL+
Ciare HS25019 +10.242 -0.05194 -298 -193.6 +2usable70 W vs 170 W: lower power handling · Xmax 8 mm < 9 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le 26W/4867T00 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.