Scan-Speak 26W/4558T00
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 21 Hz |
| Qts | 0.312 |
| Qes | 0.33 |
| Qms | 5.56 |
| Vas | 94.9 L |
| Sd | 352 cm² |
| Xmax | 6.3 mm |
| Re | 2.6 Ω |
| Bl | 10.5 T·m |
| Mms | 105.1 g |
| Pe | 80 W |
| Sensibilité | 91.1 dB |
Indication d'alignement
| EBP | 64 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 22.9 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Peerless XXLS-835016 | 22.4 +1.4 | 0.315 = | 94.4 -0.5 | 7.1 +0.8 | 91.9 +0.8 | close | + | |
| Peerless XXLS-830951 | 21 = | 0.308 = | 103 +8.1 | 10.1 +3.8 | 91.6 +0.5 | close | + | |
| SEAS L26ROY | 22 +1 | 0.306 -0.01 | 87 -7.9 | 7 +0.7 | 90.6 -0.5 | close | + | |
| Dayton Audio RS270-4 | 20.9 -0.1 | 0.277 -0.03 | 98.6 +3.7 | 6 -0.3 | 89.2 -1.9 | close | Xmax 6 mm < 6.3 mm: lower excursion-limited SPL | + |
| Peerless NE265W-08 | 23 +2 | 0.301 -0.01 | 97.2 +2.3 | 9.4 +3.1 | 88.9 -2.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Vifa NE-265W-08 | 23 +2 | 0.301 -0.01 | 97.2 +2.3 | 9.4 +3.1 | 88.9 -2.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Scan-Speak 28W/8878T01 | 22 +1 | 0.312 = | 116 +21.1 | 7.5 +1.2 | 88.7 -2.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio RS270P-4A | 22.9 +1.9 | 0.272 -0.04 | 110.5 +15.6 | 6 -0.3 | 91 -0.1 | close | Xmax 6 mm < 6.3 mm: lower excursion-limited SPL | + |
| SB Acoustics SB29NRX75-6 | 21 = | 0.356 +0.04 | 102 +7.1 | 11 +4.7 | 88.7 -2.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Dayton Audio RS270P-8A | 22.9 +1.9 | 0.319 +0.01 | 110.5 +15.6 | 6 -0.3 | 87.7 -3.4 | usable | 8 Ω vs 4 Ω: amp load changes · Xmax 6 mm < 6.3 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 26W/4558T00 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.