Scan-Speak 25W/8567-SE
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 22 Hz |
| Qts | 0.367 |
| Qes | 0.41 |
| Qms | 3.5 |
| Vas | 159 L |
| Sd | 330 cm² |
| Xmax | 7.5 mm |
| Re | 6 Ω |
| Bl | 10.1 T·m |
| Mms | 50.2 g |
| Pe | 150 W |
| Sensibilité | 89.4 dB |
Indication d'alignement
| EBP | 54 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 58.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Peerless 850146 | 22.6 +0.6 | 0.346 -0.02 | 144.4 -14.6 | 7.5 = | 89.8 +0.4 | close | + | |
| Peerless CSX 257 H | 22.6 +0.6 | 0.346 -0.02 | 144.4 -14.6 | 9 +1.5 | 89.8 +0.4 | close | + | |
| Focal 10V 516J | 22.3 +0.3 | 0.39 +0.02 | 180 +21 | 7.5 = | 90.7 +1.3 | close | + | |
| SEAS W26FX001 | 20 -2 | 0.349 -0.02 | 162 +3 | 7 -0.5 | 88 -1.4 | close | Xmax 7 mm < 7.5 mm: lower excursion-limited SPL | + |
| Peerless 831727 | 22.3 +0.3 | 0.332 -0.03 | 136.2 -22.8 | 9 +1.5 | 89.7 +0.3 | close | 110 W vs 150 W: lower power handling | + |
| Audiotechnology 10A7725KAP | 23 +1 | 0.41 +0.04 | 139 -20 | 8.6 +1.1 | 89.5 +0.1 | close | + | |
| SEAS L26RFX | 20 -2 | 0.341 -0.03 | 166 +7 | 7 -0.5 | 88.2 -1.2 | close | Xmax 7 mm < 7.5 mm: lower excursion-limited SPL | + |
| Accuton AS250-8-552 | 20 -2 | 0.327 -0.04 | 159 = | 9 +1.5 | 87.6 -1.8 | close | 16 Ω vs 8 Ω: amp load changes | + |
| Scan-Speak 26W/8534G00 v2011 | 23 +1 | 0.402 +0.04 | 150 -9 | 6 -1.5 | 89.8 +0.4 | close | 80 W vs 150 W: lower power handling · Xmax 6 mm < 7.5 mm: lower excursion-limited SPL | + |
| SEAS L26RFX/P | 20 -2 | 0.33 -0.04 | 171 +12 | 7 -0.5 | 88.5 -0.9 | close | Xmax 7 mm < 7.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 25W/8567-SE →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.