Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 66 Hz |
| Qts | 0.518 |
| Qes | 0.55 |
| Qms | 8.98 |
| Vas | 31.1 L |
| Sd | 543.3 cm² |
| Xmax | 3.9 mm |
| Re | 5.4 Ω |
| Bl | 17.7 T·m |
| Mms | 77.4 g |
| Pe | 400 W |
| Sensibilité | 95.8 dB |
Indication d'alignement
| EBP | 120 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 36 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| 18 Sound 12NTLW2500 | 62 -4 | 0.5 -0.02 | 42 +10.9 | 7.6 +3.7 | 97 +1.2 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| P.Audio EM12-LB600 | 62 -4 | 0.431 -0.09 | 39.8 +8.7 | 4 +0.1 | 96.7 +0.9 | usable | + | |
| 18 Sound 12NTLW3500 | 57 -9 | 0.54 +0.02 | 40 +8.9 | 7.9 +4 | 95 -0.8 | usable | 16 Ω vs 8 Ω: amp load changes | + |
| P.Audio E12-300S | 62 -4 | 0.49 -0.03 | 49.05 +17.95 | 3.4 -0.5 | 95.3 -0.5 | usable | 200 W vs 400 W: lower power handling · Xmax 3.4 mm < 3.9 mm: lower excursion-limited SPL | + |
| Celestion TF1230 | 59 -7 | 0.515 = | 51.25 +20.15 | 4.8 +0.9 | 94 -1.8 | usable | + | |
| RCF L12/565K | 63 -3 | 0.56 +0.04 | 57 +25.9 | 4 +0.1 | 95.7 -0.1 | usable | 200 W vs 400 W: lower power handling | + |
| P.Audio E12-200S | 59.7 -6.3 | 0.475 -0.04 | 49.1 +18 | 3.5 -0.4 | 96.6 +0.8 | usable | 200 W vs 400 W: lower power handling · Xmax 3.5 mm < 3.9 mm: lower excursion-limited SPL | + |
| Beyma 12MCS500-8 | 62 -4 | 0.417 -0.1 | 44 +12.9 | 4.9 +1 | 97.2 +1.4 | usable | + | |
| Celestion TF 1225 | 63 -3 | 0.5 -0.02 | 54.5 +23.4 | 3.5 -0.4 | 97.9 +2.1 | usable | 300 W vs 400 W: lower power handling · Xmax 3.5 mm < 3.9 mm: lower excursion-limited SPL | + |
| P.Audio SN-12MB mk2 | 62 -4 | 0.413 -0.11 | 43.6 +12.5 | 5 +1.1 | 97.6 +1.8 | usable | + |
Comparer les 3 plus proches avec le 12MWN400D →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.