← tous les HP

Rockford Fosgate T1D412

12" · 8 Ω · 800 W · 85.8 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance8 Ω
Fs29.2 Hz
Qts0.613
Qes0.71
Qms4.5
Vas55.8 L
Sd548 cm²
Xmax10.9 mm
Re6.5 Ω
Bl19.4 T·m
Mms224.1 g
Pe800 W
Sensibilité85.8 dB

Indication d'alignement

EBP41 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 168.8 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Alpine SWE-124231 +1.80.66 +0.0561 +5.211.7 +0.885.9 +0.1close4 Ω vs 8 Ω: amp load changes · 250 W vs 800 W: lower power handling+
Soundstream STEALTH-12429.98 +0.780.687 +0.0759.5 +3.713 +2.184.8 -1close350 W vs 800 W: lower power handling+
Rockford Fosgate T0D41226 -3.20.529 -0.0855.1 -0.710.7 -0.285.3 -0.5closeXmax 10.7 mm < 10.9 mm: lower excursion-limited SPL+
Dayton Audio UMII12-2231 +1.80.564 -0.0553 -2.810 -0.988.2 +2.4closeXmax 10 mm < 10.9 mm: lower excursion-limited SPL+
Dayton Audio UM12-22 v201726.2 -30.594 -0.0246.8 -99.9 -186.7 +0.9close4 Ω vs 8 Ω: amp load changes · 600 W vs 800 W: lower power handling · Xmax 9.9 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate T1D21228 -1.20.522 -0.0955.8 =10.9 =89.1 +3.3close4 Ω vs 8 Ω: amp load changes+
Alpine SWE-124131 +1.80.653 +0.0461 +5.211.3 +0.489.6 +3.8close4 Ω vs 8 Ω: amp load changes · 600 W vs 800 W: lower power handling+
Cerwin-Vega VEGA 12430.3 +1.10.612 =60.3 +4.57 -3.986.4 +0.6close400 W vs 800 W: lower power handling · Xmax 7 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate P3D4-1227.7 -1.50.517 -0.157.7 +1.99.4 -1.586.3 +0.5close600 W vs 800 W: lower power handling · Xmax 9.4 mm < 10.9 mm: lower excursion-limited SPL+
Audiomobile ELITE 221228 -1.20.48 -0.1359.46 +3.6612.7 +1.885.8 =close4 Ω vs 8 Ω: amp load changes · 600 W vs 800 W: lower power handling+

Comparer les 3 plus proches avec le T1D412 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.