Rockford Fosgate T1D212

12" · 4 Ω · 800 W · 89.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale12"
Impédance4 Ω
Fs28 Hz
Qts0.522
Qes0.59
Qms4.5
Vas55.8 L
Sd548 cm²
Xmax10.9 mm
Re3.25 Ω
Bl15.4 T·m
Mms243.7 g
Pe800 W
Sensibilité89.1 dB

Indication d'alignement

EBP47 · sealed
Sealed Vb (Qtc ≈ 0.71)≈ 66.8 L

EBP < 50 : favorise un alignement clos.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
JL Audio 13TW5V2-227.6 -0.40.526 =60.3 +4.59 -1.989.2 +0.1close600 W vs 800 W: lower power handling · Xmax 9 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate P3D2-1226.5 -1.50.491 -0.0357.7 +1.99.5 -1.489 -0.1close600 W vs 800 W: lower power handling · Xmax 9.5 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate P3D4-1227.7 -0.30.517 -0.0157.7 +1.99.4 -1.586.3 -2.8close8 Ω vs 4 Ω: amp load changes · 600 W vs 800 W: lower power handling · Xmax 9.4 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate T0D41226 -20.529 +0.0155.1 -0.710.7 -0.285.3 -3.8close8 Ω vs 4 Ω: amp load changes · Xmax 10.7 mm < 10.9 mm: lower excursion-limited SPL+
Rockford Fosgate T0D21225.3 -2.70.473 -0.0555 -0.810.5 -0.488 -1.1closeXmax 10.5 mm < 10.9 mm: lower excursion-limited SPL+
Audiomobile ELITE 221228 =0.48 -0.0459.46 +3.6612.7 +1.885.8 -3.3close600 W vs 800 W: lower power handling+
Dayton Audio UMII12-2231 +30.564 +0.0453 -2.810 -0.988.2 -0.9close8 Ω vs 4 Ω: amp load changes · Xmax 10 mm < 10.9 mm: lower excursion-limited SPL+
Sound Storm Labs CR12D30.7 +2.70.522 =66.9 +11.110.3 -0.687.5 -1.6close8 Ω vs 4 Ω: amp load changes · 600 W vs 800 W: lower power handling · Xmax 10.3 mm < 10.9 mm: lower excursion-limited SPL+
Audio System HX12 SQ28.2 +0.20.5 -0.0268 +12.211.8 +0.986.1 -3close450 W vs 800 W: lower power handling+
Rockford Fosgate T1D41229.2 +1.20.613 +0.0955.8 =10.9 =85.8 -3.3close8 Ω vs 4 Ω: amp load changes+

Comparer les 3 plus proches avec le T1D212 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.