RCF LF 18X400
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 28 Hz |
| Qts | 0.255 |
| Qes | 0.27 |
| Qms | 4.5 |
| Vas | 360 L |
| Sd | 1231.1 cm² |
| Xmax | 9 mm |
| Re | 5.1 Ω |
| Bl | 25.2 T·m |
| Mms | 190.7 g |
| Pe | 1000 W |
| Sensibilité | 98.6 dB |
Indication d'alignement
| EBP | 104 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 53.8 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| RCF LF 18G400 | 28 = | 0.273 +0.02 | 360 = | 9 = | 98.3 -0.3 | close | + | |
| RCF LF18G400 | 28 = | 0.27 +0.02 | 360 = | 9 = | 97.5 -1.1 | close | + | |
| RCF LF18X400 | 28 = | 0.27 +0.02 | 340 -20 | 9 = | 97.5 -1.1 | close | + | |
| RCF LF 18X400 v2 | 28 = | 0.278 +0.02 | 340 -20 | 9 = | 98 -0.6 | close | + | |
| Faital PRO 18FH510 | 30 +2 | 0.26 +0.01 | 391.4 +31.4 | 9.45 +0.45 | 98 -0.6 | close | 4 Ω vs 8 Ω: amp load changes · 600 W vs 1000 W: lower power handling | + |
| RCF L 18P400 | 29 +1 | 0.279 +0.02 | 340 -20 | 8.8 -0.2 | 98.5 -0.1 | close | Xmax 8.8 mm < 9 mm: lower excursion-limited SPL | + |
| PD PD 182 | 28 = | 0.238 -0.02 | 391 +31 | 8.2 -0.8 | 98.7 +0.1 | close | 600 W vs 1000 W: lower power handling · Xmax 8.2 mm < 9 mm: lower excursion-limited SPL | + |
| Precision Devices PD 182 | 28 = | 0.238 -0.02 | 391 +31 | 8.2 -0.8 | 98.7 +0.1 | close | 600 W vs 1000 W: lower power handling · Xmax 8.2 mm < 9 mm: lower excursion-limited SPL | + |
| B&C 18 PZB 46 vp | 28.8 +0.8 | 0.227 -0.03 | 346.4 -13.6 | 8.1 -0.9 | 99 +0.4 | close | 700 W vs 1000 W: lower power handling · Xmax 8.1 mm < 9 mm: lower excursion-limited SPL | + |
| 18 Sound 18ND9300 | 30 +2 | 0.28 +0.03 | 322 -38 | 9.5 +0.5 | 98.8 +0.2 | close | + |
Comparer les 3 plus proches avec le LF 18X400 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.