RCF LF 15G302 vp baptiste

15" · 8 Ω · 800 W · 97.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance8 Ω
Fs56.8 Hz
Qts0.561
Qes0.611
Qms6.873
Vas87 L
Sd908 cm²
Xmax6 mm
Re6.48 Ω
Bl19.9 T·m
Mms104.4 g
Pe800 W
Sensibilité97.1 dB

Indication d'alignement

EBP93 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 147.8 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
PD PD 156 v201450.3 -6.50.469 -0.0993.4 +6.45.7 -0.397.2 +0.1usableXmax 5.7 mm < 6 mm: lower excursion-limited SPL+
Precision Devices PD 156 v201450.3 -6.50.469 -0.0993.4 +6.45.7 -0.397.2 +0.1usableXmax 5.7 mm < 6 mm: lower excursion-limited SPL+
Celestion BL15-400X54.2 -2.60.592 +0.03110.9 +23.94.8 -1.297.3 +0.2usable400 W vs 800 W: lower power handling · Xmax 4.8 mm < 6 mm: lower excursion-limited SPL+
Beyma 15CM V249 -7.80.49 -0.07104 +177 +197 -0.1usable350 W vs 800 W: lower power handling+
the box Speaker 15-300/8-A52.6 -4.20.64 +0.08100.3 +13.34.6 -1.496.8 -0.3usable300 W vs 800 W: lower power handling · Xmax 4.6 mm < 6 mm: lower excursion-limited SPL+
Focal 38KXSPL45.8 -110.55 -0.01116.4 +29.45.5 -0.598 +0.9usable4 Ω vs 8 Ω: amp load changes · 500 W vs 800 W: lower power handling · Xmax 5.5 mm < 6 mm: lower excursion-limited SPL+
P.Audio E15-LF50 -6.80.42 -0.1492.17 +5.176 =95.9 -1.2usable+
DAP Audio AB-1546.7 -10.10.546 -0.02122.3 +35.35.5 -0.595.4 -1.7usable400 W vs 800 W: lower power handling · Xmax 5.5 mm < 6 mm: lower excursion-limited SPL+
Beyma 15CMV2 v202149 -7.80.485 -0.08104 +174.5 -1.596.7 -0.4usable350 W vs 800 W: lower power handling · Xmax 4.5 mm < 6 mm: lower excursion-limited SPL+
JBL 615H55 -1.80.603 +0.04112 +253.7 -2.398.1 +1usable175 W vs 800 W: lower power handling · Xmax 3.7 mm < 6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le LF 15G302 vp baptiste →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.