RCF L12/565K
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 63 Hz |
| Qts | 0.56 |
| Qes | 0.58 |
| Qms | 16.6 |
| Vas | 57 L |
| Sd | 530 cm² |
| Xmax | 4 mm |
| Re | 5.8 Ω |
| Bl | 13.3 T·m |
| Mms | 43 g |
| Pe | 200 W |
| Sensibilité | 95.7 dB |
Indication d'alignement
| EBP | 109 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 95.9 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| P.Audio E12-200S v2024 | 59 -4 | 0.569 +0.01 | 62 +5 | 4.1 +0.1 | 96.4 +0.7 | close | + | |
| HH Electronics DC100LW | 60 -3 | 0.56 = | 56.6 -0.4 | 3.2 -0.8 | 95.2 -0.5 | close | 100 W vs 200 W: lower power handling · Xmax 3.2 mm < 4 mm: lower excursion-limited SPL | + |
| RCF L 12/565K | 63 = | 0.56 = | 57 = | 2.9 -1.1 | 97.3 +1.6 | close | 100 W vs 200 W: lower power handling · Xmax 2.9 mm < 4 mm: lower excursion-limited SPL | + |
| Celestion TF 1225 | 63 = | 0.5 -0.06 | 54.5 -2.5 | 3.5 -0.5 | 97.9 +2.2 | close | Xmax 3.5 mm < 4 mm: lower excursion-limited SPL | + |
| Celestion TF1230 | 59 -4 | 0.515 -0.05 | 51.25 -5.75 | 4.8 +0.8 | 94 -1.7 | close | + | |
| Celestion BN12-300X | 56.2 -6.8 | 0.479 -0.08 | 61.2 +4.2 | 4 = | 96.1 +0.4 | close | + | |
| JB Systems PWX12-200 | 59.4 -3.6 | 0.474 -0.09 | 55.5 -1.5 | 3.6 -0.4 | 96.5 +0.8 | close | Xmax 3.6 mm < 4 mm: lower excursion-limited SPL | + |
| SICA 12 C 2 CP | 63 = | 0.509 -0.05 | 70 +13 | 4.2 +0.2 | 98 +2.3 | close | + | |
| P.Audio E12-300S | 62 -1 | 0.49 -0.07 | 49.05 -7.95 | 3.4 -0.6 | 95.3 -0.4 | close | Xmax 3.4 mm < 4 mm: lower excursion-limited SPL | + |
| RCF L12CX2K | 59.7 -3.3 | 0.46 -0.1 | 65 +8 | 4 = | 96.3 +0.6 | usable | 75 W vs 200 W: lower power handling | + |
Comparer les 3 plus proches avec le L12/565K →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.