RCF L 15P200AK-I
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 38 Hz |
| Qts | 0.36 |
| Qes | 0.38 |
| Qms | 6.8 |
| Vas | 139 L |
| Sd | 830 cm² |
| Xmax | 8.5 mm |
| Re | 5.9 Ω |
| Bl | 21.3 T·m |
| Mms | 121.9 g |
| Pe | 800 W |
| Sensibilité | 96.3 dB |
Indication d'alignement
| EBP | 100 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 48.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| RCF L 15P200AK | 38 = | 0.351 -0.01 | 139 = | 8.2 -0.3 | 96.4 +0.1 | close | Xmax 8.2 mm < 8.5 mm: lower excursion-limited SPL | + |
| RCF L 15P200AK-II | 38 = | 0.336 -0.02 | 139 = | 8.3 -0.2 | 96.3 = | close | Xmax 8.3 mm < 8.5 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH530 | 39 +1 | 0.35 -0.01 | 140.6 +1.6 | 9.25 +0.75 | 97 +0.7 | close | 500 W vs 800 W: lower power handling | + |
| Peavey 15 LOW MAX | 38.2 +0.2 | 0.352 -0.01 | 125.6 -13.4 | 9.8 +1.3 | 96 -0.3 | close | + | |
| Peavey LO MAX 15 v2011 | 38.5 +0.5 | 0.352 -0.01 | 124 -15 | 9.2 +0.7 | 96.6 +0.3 | close | + | |
| PD PDN 15BR40-V2 | 39.2 +1.2 | 0.376 +0.02 | 140.1 +1.1 | 8.2 -0.3 | 97.3 +1 | close | Xmax 8.2 mm < 8.5 mm: lower excursion-limited SPL | + |
| Precision Devices PDN 15BR40-V2 | 39.2 +1.2 | 0.376 +0.02 | 140.1 +1.1 | 8.2 -0.3 | 97.3 +1 | close | Xmax 8.2 mm < 8.5 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH520 | 38 = | 0.34 -0.02 | 153.2 +14.2 | 9.15 +0.65 | 97 +0.7 | close | 4 Ω vs 8 Ω: amp load changes · 600 W vs 800 W: lower power handling | + |
| Sica 15 PNS 4 | 37.3 -0.7 | 0.35 -0.01 | 116.3 -22.7 | 9 +0.5 | 96 -0.3 | close | + | |
| Faital PRO 15FH520 v2018 | 38 = | 0.394 +0.03 | 156.6 +17.6 | 8.5 = | 96.7 +0.4 | close | 600 W vs 800 W: lower power handling | + |
Comparer les 3 plus proches avec le L 15P200AK-I →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.