RCF L 15P02 vp FREDO51
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 80 Hz |
| Qts | 0.518 |
| Qes | 0.59 |
| Qms | 4.26 |
| Vas | 77 L |
| Sd | 855 cm² |
| Xmax | 2.4 mm |
| Re | 6.5 Ω |
| Bl | 17.1 T·m |
| Mms | 52.7 g |
| Pe | 200 W |
| Sensibilité | 101.1 dB |
Indication d'alignement
| EBP | 136 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 89.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Audax PR380T2 | 52 -28 | 0.522 = | 92 +15 | 2.7 +0.3 | 99.4 -1.7 | usable | 4 Ω vs 8 Ω: amp load changes · 150 W vs 200 W: lower power handling | + |
| P.Audio R15/76MB | 62.5 -17.5 | 0.421 -0.1 | 83.4 +6.4 | 4.2 +1.8 | 100 -1.1 | usable | + | |
| Jensen NEO 15-150-16 | 74.8 -5.2 | 0.673 +0.16 | 65.6 -11.4 | 2 -0.4 | 99.3 -1.8 | usable | 150 W vs 200 W: lower power handling · Xmax 2 mm < 2.4 mm: lower excursion-limited SPL | + |
| Audax PR380T0 vp_g | 56.9 -23.1 | 0.537 +0.02 | 108.5 +31.5 | 2.8 +0.4 | 98.6 -2.5 | usable | 150 W vs 200 W: lower power handling | + |
| RCF LF 15G302 vp baptiste | 56.8 -23.2 | 0.561 +0.04 | 87 +10 | 6 +3.6 | 97.1 -4 | usable | + | |
| Eminence LEGEND CA154 | 51.1 -28.9 | 0.487 -0.03 | 108.2 +31.2 | 4.5 +2.1 | 100.6 -0.5 | usable | 4 Ω vs 8 Ω: amp load changes | + |
| JBL 2032H | 57 -23 | 0.541 +0.02 | 133.1 +56.1 | 4.6 +2.2 | 100.9 -0.2 | usable | + | |
| RCF L 17/64AF vp FREDO51 | 60 -20 | 0.388 -0.13 | 109 +32 | 2.8 +0.4 | 101.2 +0.1 | usable | 150 W vs 200 W: lower power handling | + |
| ATC PA75-375 STD | 60 -20 | 0.398 -0.12 | 82 +5 | 1.6 -0.8 | 99.6 -1.5 | usable | 75 W vs 200 W: lower power handling · Xmax 1.6 mm < 2.4 mm: lower excursion-limited SPL | + |
| Celestion BN15-300S-4 | 50 -30 | 0.537 +0.02 | 138.9 +61.9 | 2.5 +0.1 | 101.4 +0.3 | usable | 4 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le L 15P02 vp FREDO51 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.