Radian 5215 B-8
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 38.7 Hz |
| Qts | 0.316 |
| Qes | 0.35 |
| Qms | 3.24 |
| Vas | 189.7 L |
| Sd | 789 cm² |
| Xmax | 5.5 mm |
| Re | 6 Ω |
| Bl | 18 T·m |
| Mms | 77.8 g |
| Pe | 625 W |
| Sensibilité | 98.2 dB |
Indication d'alignement
| EBP | 111 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 47.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Radian 5215B | 39 +0.3 | 0.313 = | 192.4 +2.7 | 5.5 = | 98.5 +0.3 | close | + | |
| Fane SOVEREIGN PRO 15-500 | 40 +1.3 | 0.319 = | 192 +2.3 | 6 +0.5 | 99.4 +1.2 | close | + | |
| Audax PR38ST250 | 38 -0.7 | 0.311 -0.01 | 193 +3.3 | 4.9 -0.6 | 98.4 +0.2 | close | 250 W vs 625 W: lower power handling · Xmax 4.9 mm < 5.5 mm: lower excursion-limited SPL | + |
| RCF L 15L601 | 38 -0.7 | 0.305 -0.01 | 190 +0.3 | 5 -0.5 | 97.9 -0.3 | close | Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| PHL Audio 5102 | 36 -2.7 | 0.306 -0.01 | 190 +0.3 | 6.1 +0.6 | 97.8 -0.4 | close | 400 W vs 625 W: lower power handling | + |
| 18 Sound 15ND830 | 39 +0.3 | 0.32 = | 213 +23.3 | 6.5 +1 | 98 -0.2 | close | 450 W vs 625 W: lower power handling | + |
| PHL Audio 5100 | 39 +0.3 | 0.297 -0.02 | 180 -9.7 | 5.6 +0.1 | 98.8 +0.6 | close | 400 W vs 625 W: lower power handling | + |
| RCF MB 15X301 | 38 -0.7 | 0.345 +0.03 | 195 +5.3 | 6 +0.5 | 98.3 +0.1 | close | + | |
| JBL 265H-1 | 39 +0.3 | 0.32 = | 170 -19.7 | 5 -0.5 | 98.3 +0.1 | close | 300 W vs 625 W: lower power handling · Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| LaVoce WAF154.03 | 38 -0.7 | 0.29 -0.03 | 188 -1.7 | 5.2 -0.3 | 98.6 +0.4 | close | Xmax 5.2 mm < 5.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 5215 B-8 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.