Radian 5212-8
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 45.1 Hz |
| Qts | 0.489 |
| Qes | 0.57 |
| Qms | 3.46 |
| Vas | 87.9 L |
| Sd | 515 cm² |
| Xmax | 5 mm |
| Re | 6.1 Ω |
| Bl | 12.6 T·m |
| Mms | 52.7 g |
| Pe | 375 W |
| Sensibilité | 94.7 dB |
Indication d'alignement
| EBP | 79 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 80.6 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence BASSLITE S2012 | 48 +2.9 | 0.48 -0.01 | 91 +3.1 | 5.2 +0.2 | 94.6 -0.1 | close | 150 W vs 375 W: lower power handling | + |
| Davis 31TCA12 vp 2018 CLIO POCKET | 45.8 +0.7 | 0.455 -0.03 | 86.8 -1.1 | 5 = | 95 +0.3 | close | 200 W vs 375 W: lower power handling | + |
| PHL Audio 4540 vp essais | 45.8 +0.7 | 0.456 -0.03 | 87.8 -0.1 | 6 +1 | 94.8 +0.1 | close | + | |
| Beyma SM212 vp Nº1 | 45.8 +0.7 | 0.456 -0.03 | 87.1 -0.8 | 6.5 +1.5 | 94.8 +0.1 | close | + | |
| PHL Audio 4530 vp2 | 45.8 +0.7 | 0.454 -0.03 | 86.8 -1.1 | 6 +1 | 95 +0.3 | close | + | |
| Davis 31TCA12 vp2015 n2 | 48.5 +3.4 | 0.471 -0.02 | 85.1 -2.8 | 4.9 -0.1 | 95.6 +0.9 | close | 200 W vs 375 W: lower power handling · Xmax 4.9 mm < 5 mm: lower excursion-limited SPL | + |
| Audax 330 vp | 45.8 +0.7 | 0.454 -0.03 | 86.8 -1.1 | 4.3 -0.7 | 95 +0.3 | close | 150 W vs 375 W: lower power handling · Xmax 4.3 mm < 5 mm: lower excursion-limited SPL | + |
| PHL Audio 4530 vp clio p | 47.1 +2 | 0.46 -0.03 | 93.2 +5.3 | 6 +1 | 95.7 +1 | close | + | |
| Faital PRO 12PR300 | 50 +4.9 | 0.49 = | 89.7 +1.8 | 4.92 -0.08 | 97 +2.3 | close | 16 Ω vs 8 Ω: amp load changes · Xmax 4.92 mm < 5 mm: lower excursion-limited SPL | + |
| Faital PRO 12FE300 | 47 +1.9 | 0.51 +0.02 | 83.7 -4.2 | 5.07 +0.07 | 97 +2.3 | close | 250 W vs 375 W: lower power handling | + |
Comparer les 3 plus proches avec le 5212-8 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.