Radian 512/2 BK-8
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 45.1 Hz |
| Qts | 0.489 |
| Qes | 0.57 |
| Qms | 3.46 |
| Vas | 106.8 L |
| Sd | 515 cm² |
| Xmax | 0.9 mm |
| Re | 7 Ω |
| Bl | 12.3 T·m |
| Mms | 43.3 g |
| Pe | 300 W |
| Sensibilité | 94.9 dB |
Indication d'alignement
| EBP | 79 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 97.9 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Monacor SP-12 vp nº1 | 45.8 +0.7 | 0.458 -0.03 | 104.3 -2.5 | 3.9 +3 | 95.6 +0.7 | close | 100 W vs 300 W: lower power handling | + |
| Radian 5212-8 | 45.1 = | 0.489 = | 87.9 -18.9 | 5 +4.1 | 94.7 -0.2 | usable | + | |
| Celestion PULSE12 | 45 -0.1 | 0.42 -0.07 | 104.77 -2.03 | 3.8 +2.9 | 94.7 -0.2 | usable | 200 W vs 300 W: lower power handling | + |
| Altec 417-16LF | 47.7 +2.6 | 0.376 -0.11 | 107 +0.2 | 1.3 +0.4 | 94.8 -0.1 | usable | 16 Ω vs 8 Ω: amp load changes · 100 W vs 300 W: lower power handling | + |
| Dayton Audio 310-8 | 44.4 -0.7 | 0.482 -0.01 | 81.9 -24.9 | 3.5 +2.6 | 94.9 = | usable | 80 W vs 300 W: lower power handling | + |
| PHL Audio 4530 vp | 45.8 +0.7 | 0.45 -0.04 | 104.5 -2.3 | 6 +5.1 | 95.8 +0.9 | usable | + | |
| Eminence BETA-12LTA | 45 -0.1 | 0.51 +0.02 | 136.3 +29.5 | 3.2 +2.3 | 95.4 +0.5 | usable | 225 W vs 300 W: lower power handling | + |
| Siare 31TE vp 2 | 41.3 -3.8 | 0.506 +0.02 | 99.9 -6.9 | 4.7 +3.8 | 95.6 +0.7 | usable | 120 W vs 300 W: lower power handling | + |
| Altec 920-8A | 48 +2.9 | 0.501 +0.01 | 141.6 +34.8 | 1.3 +0.4 | 96.9 +2 | usable | 125 W vs 300 W: lower power handling | + |
| University Sound 312 200 | 50.5 +5.4 | 0.503 +0.01 | 85 -21.8 | 2 +1.1 | 94.4 -0.5 | usable | 35 W vs 300 W: lower power handling | + |
Comparer les 3 plus proches avec le 512/2 BK-8 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.