Powerbass S-12T
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 34.4 Hz |
| Qts | 0.634 |
| Qes | 0.758 |
| Qms | 3.9 |
| Vas | 45.92 L |
| Sd | 531 cm² |
| Xmax | 6.9 mm |
| Re | 3.2 Ω |
| Bl | 13 T·m |
| Mms | 186.3 g |
| Pe | 300 W |
| Sensibilité | 85.8 dB |
Indication d'alignement
| EBP | 45 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 188.3 L |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Hertz Audio ES 300.5 | 35 +0.6 | 0.66 +0.03 | 48.5 +2.58 | 9 +2.1 | 86.6 +0.8 | close | + | |
| American Bass DX 12 | 35.6 +1.2 | 0.6 -0.03 | 41.5 -4.42 | 12 +5.1 | 86.2 +0.4 | close | + | |
| Ground Zero GZIW 300X | 34.9 +0.5 | 0.69 +0.06 | 53.6 +7.68 | 7.5 +0.6 | 86.6 +0.8 | close | + | |
| Sony XS-L124P5B | 33.1 -1.3 | 0.626 -0.01 | 44.5 -1.42 | 6 -0.9 | 88.8 +3 | close | Xmax 6 mm < 6.9 mm: lower excursion-limited SPL | + |
| hertz Hertz Audio ES300.5 | 35 +0.6 | 0.66 +0.03 | 48.5 +2.58 | 6.8 -0.1 | 90.8 +5 | close | Xmax 6.8 mm < 6.9 mm: lower excursion-limited SPL | + |
| Ground Zero GZIW 12XSPL-D2 | 32.5 -1.9 | 0.736 +0.1 | 40.4 -5.52 | 7.6 +0.7 | 87.1 +1.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Cerwin-Vega VEGA 124 | 30.3 -4.1 | 0.612 -0.02 | 60.3 +14.38 | 7 +0.1 | 86.4 +0.6 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Rockford Fosgate T1D412 | 29.2 -5.2 | 0.613 -0.02 | 55.8 +9.88 | 10.9 +4 | 85.8 = | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Selenium 12SW3A DVC 2+2 | 35 +0.6 | 0.724 +0.09 | 49 +3.08 | 6.5 -0.4 | 89.6 +3.8 | usable | Xmax 6.5 mm < 6.9 mm: lower excursion-limited SPL | + |
| Pioneer TS-W308D4 | 34.5 +0.1 | 0.625 -0.01 | 34.7 -11.22 | 6.4 -0.5 | 89.4 +3.6 | usable | Xmax 6.4 mm < 6.9 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le S-12T →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.