Pioneer TS-W307D2
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 2 Ω |
| Fs | 33.9 Hz |
| Qts | 0.435 |
| Qes | 0.45 |
| Qms | 13.17 |
| Vas | 42.2 L |
| Sd | 460 cm² |
| Xmax | 7.1 mm |
| Re | 1.5 Ω |
| Bl | 10.5 T·m |
| Mms | 154.9 g |
| Pe | 400 W |
| Sensibilité | 94.9 dB |
Indication d'alignement
| EBP | 75 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 25.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Gladen SQX12 | 36.7 +2.8 | 0.405 -0.03 | 40.9 -1.3 | 7 -0.1 | 92.6 -2.3 | close | 4 Ω vs 2 Ω: amp load changes · Xmax 7 mm < 7.1 mm: lower excursion-limited SPL | + |
| Celestion FTR12-4080DL/4 | 35.3 +1.4 | 0.428 -0.01 | 51.4 +9.2 | 8 +0.9 | 92.5 -2.4 | close | 4 Ω vs 2 Ω: amp load changes | + |
| Massive Audio REBEL 124 | 32.6 -1.3 | 0.485 +0.05 | 38 -4.2 | 7.1 = | 92.4 -2.5 | close | + | |
| Dayton Audio TITANIC | 36.3 +2.4 | 0.506 +0.07 | 44 +1.8 | 7.4 +0.3 | 92 -2.9 | usable | 4 Ω vs 2 Ω: amp load changes | + |
| Pioneer TS-W306C | 32.6 -1.3 | 0.414 -0.02 | 55.6 +13.4 | 8.1 +1 | 92.8 -2.1 | usable | 4 Ω vs 2 Ω: amp load changes | + |
| DD Audio REDLINE 700 SERIES | 28.3 -5.6 | 0.434 = | 39.6 -2.6 | 7 -0.1 | 90.7 -4.2 | usable | 4 Ω vs 2 Ω: amp load changes · Xmax 7 mm < 7.1 mm: lower excursion-limited SPL | + |
| Pioneer TS-W307D4 | 34.8 +0.9 | 0.52 +0.09 | 40.9 -1.3 | 7.4 +0.3 | 91.3 -3.6 | usable | 4 Ω vs 2 Ω: amp load changes | + |
| JBL P1220 | 28.7 -5.2 | 0.448 +0.01 | 47.4 +5.2 | 7.8 +0.7 | 91.8 -3.1 | usable | + | |
| JBL 1200 GTI | 37 +3.1 | 0.47 +0.03 | 56.7 +14.5 | 8 +0.9 | 94.5 -0.4 | usable | 4 Ω vs 2 Ω: amp load changes | + |
| Focal P30DB | 29.4 -4.5 | 0.427 -0.01 | 56.8 +14.6 | 7.7 +0.6 | 93.7 -1.2 | usable | + |
Comparer les 3 plus proches avec le TS-W307D2 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.