Pioneer TS-W303R
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 4 Ω |
| Fs | 24.1 Hz |
| Qts | 0.637 |
| Qes | 0.76 |
| Qms | 3.94 |
| Vas | 86.3 L |
| Sd | 471 cm² |
| Xmax | 5 mm |
| Re | 3.3 Ω |
| Bl | 10.2 T·m |
| Mms | 157.2 g |
| Pe | 250 W |
| Sensibilité | 87.8 dB |
Indication d'alignement
| EBP | 32 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 371.6 L |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Focal 30A4 | 24.7 +0.6 | 0.671 +0.03 | 86.9 +0.6 | 8.5 +3.5 | 87.3 -0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Focal 30A4 vp | 24.7 +0.6 | 0.671 +0.03 | 86.9 +0.6 | 8.5 +3.5 | 87.3 -0.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Pyle Audio PLD12WD vp | 25 +0.9 | 0.674 +0.04 | 77.3 -9 | 8 +3 | 86.3 -1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Peerless XXLS-P830845 v2025 | 29 +4.9 | 0.654 +0.02 | 91.9 +5.6 | 7.6 +2.6 | 88.5 +0.7 | close | 8 Ω vs 4 Ω: amp load changes · 175 W vs 250 W: lower power handling | + |
| Dayton Audio UM12-22 | 24.9 +0.8 | 0.589 -0.05 | 71.6 -14.7 | 12.5 +7.5 | 87.7 -0.1 | usable | + | |
| Rockford Fosgate P1S2-12 | 25 +0.9 | 0.55 -0.09 | 88.3 +2 | 9 +4 | 85.1 -2.7 | usable | 2 Ω vs 4 Ω: amp load changes | + |
| Rockford Fosgate P1S4-12 | 25 +0.9 | 0.55 -0.09 | 88.3 +2 | 9 +4 | 85.1 -2.7 | usable | + | |
| Monacor CRB-12TC vp série | 31 +6.9 | 0.611 -0.03 | 75 -11.3 | 4.9 -0.1 | 87.3 -0.5 | usable | 8 Ω vs 4 Ω: amp load changes · 100 W vs 250 W: lower power handling · Xmax 4.9 mm < 5 mm: lower excursion-limited SPL | + |
| Kenwood KFC-W3013 | 25 +0.9 | 0.82 +0.18 | 83.7 -2.6 | 7.6 +2.6 | 87.3 -0.5 | usable | + | |
| Rockford Fosgate P1S8-12 | 26 +1.9 | 0.593 -0.04 | 109 +22.7 | 9 +4 | 87.4 -0.4 | usable | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le TS-W303R →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.