Pioneer TS-SW251
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 4 Ω |
| Fs | 41.3 Hz |
| Qts | 1.09 |
| Qes | 1.15 |
| Qms | 9.9 |
| Vas | 9.75 L |
| Sd | 309 cm² |
| Xmax | 6.6 mm |
| Re | 3 Ω |
| Bl | 11.8 T·m |
| Mms | 206.6 g |
| Pe | 200 W |
| Sensibilité | 79.6 dB |
Indication d'alignement
| EBP | 36 · sealed |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP < 50 : favorise un alignement clos.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Pioneer TS-SW2541D | 43.5 +2.2 | 0.95 -0.14 | 8.25 -1.5 | 6 -0.6 | 80 +0.4 | usable | Xmax 6 mm < 6.6 mm: lower excursion-limited SPL | + |
| Pioneer TS-SW2502S4 | 42 +0.7 | 0.97 -0.12 | 18.5 +8.75 | 6.5 -0.1 | 83 +3.4 | usable | Xmax 6.5 mm < 6.6 mm: lower excursion-limited SPL | + |
| Pioneer TS-SW2501S4 | 41.6 +0.3 | 0.93 -0.16 | 10.3 +0.55 | 3.6 -3 | 84.9 +5.3 | usable | Xmax 3.6 mm < 6.6 mm: lower excursion-limited SPL | + |
| JL Audio 10TW1-2 | 41.45 +0.15 | 0.65 -0.44 | 10.31 +0.56 | 10.31 +3.71 | 82.5 +2.9 | usable | 2 Ω vs 4 Ω: amp load changes | + |
| Kenwood KFC-W2511 | 60 +18.7 | 0.84 -0.25 | 9.38 -0.37 | 7 +0.4 | 85.2 +5.6 | usable | + | |
| Pioneer TS-W2501D4 | 38.8 -2.5 | 0.721 -0.37 | 6.3 -3.45 | 6 -0.6 | 82.7 +3.1 | usable | Xmax 6 mm < 6.6 mm: lower excursion-limited SPL | + |
| Xtant X2 1044 | 37.2 -4.1 | 0.961 -0.13 | 15.9 +6.15 | 5.7 -0.9 | 88.5 +8.9 | risky | 2 Ω vs 4 Ω: amp load changes · Xmax 5.7 mm < 6.6 mm: lower excursion-limited SPL | + |
| Pioneer TS-W261D4 | 46 +4.7 | 1.044 -0.05 | 17.7 +7.95 | 8.4 +1.8 | 89.9 +10.3 | risky | + | |
| JL Audio 10TW1-4 | 38 -3.3 | 0.6 -0.49 | 12.15 +2.4 | 10 +3.4 | 82.2 +2.6 | risky | + | |
| Skar Audio EV-10 S4 | 50.9 +9.6 | 0.76 -0.33 | 14 +4.25 | 8.5 +1.9 | 85.2 +5.6 | risky | 150 W vs 200 W: lower power handling | + |
Comparer les 3 plus proches avec le TS-SW251 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.