PHL Audio 5200
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 38 Hz |
| Qts | 0.272 |
| Qes | 0.29 |
| Qms | 4.3 |
| Vas | 180 L |
| Sd | 892 cm² |
| Xmax | 6 mm |
| Re | 3 Ω |
| Bl | 16.4 T·m |
| Mms | 108.7 g |
| Pe | 500 W |
| Sensibilité | 101.6 dB |
Indication d'alignement
| EBP | 131 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 31.3 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Eminence PS15-5008 | 38.8 +0.8 | 0.273 = | 198.7 +18.7 | 6.3 +0.3 | 99.8 -1.8 | close | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 15 CXN 88 | 40 +2 | 0.254 -0.02 | 178 -2 | 6 = | 100.4 -1.2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| PHL Audio 5140 | 38 = | 0.245 -0.03 | 180 = | 5.7 -0.3 | 100.6 -1 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.7 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 5050 | 38 = | 0.254 -0.02 | 180 = | 5.9 -0.1 | 99.2 -2.4 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.9 mm < 6 mm: lower excursion-limited SPL | + |
| Sica 15 K 3 PL | 40 +2 | 0.27 = | 166.1 -13.9 | 6.5 +0.5 | 99.7 -1.9 | close | 8 Ω vs 4 Ω: amp load changes | + |
| B&C 15 PS 76 | 38 = | 0.266 -0.01 | 164 -16 | 6.3 +0.3 | 98.9 -2.7 | close | 8 Ω vs 4 Ω: amp load changes | + |
| PD PD 153 C01 | 39 +1 | 0.265 -0.01 | 195 +15 | 5.5 -0.5 | 100.2 -1.4 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.5 mm < 6 mm: lower excursion-limited SPL | + |
| Precision Devices PD 153 C01 | 39 +1 | 0.265 -0.01 | 195 +15 | 5.5 -0.5 | 100.2 -1.4 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 5.5 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 5012MNdU | 36 -2 | 0.268 = | 175 -5 | 6 = | 98.3 -3.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
| PHL Audio 5011 | 36 -2 | 0.268 = | 174.7 -5.3 | 6 = | 98.3 -3.3 | close | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 5200 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.