PHL Audio 5052
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 35 Hz |
| Qts | 0.254 |
| Qes | 0.27 |
| Qms | 4.4 |
| Vas | 190 L |
| Sd | 892 cm² |
| Xmax | 6.2 mm |
| Re | 5.6 Ω |
| Bl | 23.5 T·m |
| Mms | 121.4 g |
| Pe | 500 W |
| Sensibilité | 98.3 dB |
Indication d'alignement
| EBP | 130 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 28.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| PHL Audio 5010 | 34 -1 | 0.25 = | 200 +10 | 6.4 +0.2 | 98.2 -0.1 | close | + | |
| Celestion FTR15-4080F-Bis | 35 = | 0.243 -0.01 | 182.8 -7.2 | 6 -0.2 | 98.3 = | close | Xmax 6 mm < 6.2 mm: lower excursion-limited SPL | + |
| Faital PRO 15FH510 | 35 = | 0.26 +0.01 | 191.8 +1.8 | 9.25 +3.05 | 98 -0.3 | close | + | |
| PHL Audio 5051 | 37 +2 | 0.245 -0.01 | 190 = | 5.9 -0.3 | 99.2 +0.9 | close | Xmax 5.9 mm < 6.2 mm: lower excursion-limited SPL | + |
| PHL Audio 5012MNdU | 36 +1 | 0.268 +0.01 | 175 -15 | 6 -0.2 | 98.3 = | close | Xmax 6 mm < 6.2 mm: lower excursion-limited SPL | + |
| PHL Audio 5011 | 36 +1 | 0.268 +0.01 | 174.7 -15.3 | 6 -0.2 | 98.3 = | close | Xmax 6 mm < 6.2 mm: lower excursion-limited SPL | + |
| Beyma 15G400 | 35 = | 0.271 +0.02 | 175 -15 | 6.1 -0.1 | 97.5 -0.8 | close | Xmax 6.1 mm < 6.2 mm: lower excursion-limited SPL | + |
| 18 Sound 15ND930 | 35 = | 0.24 -0.01 | 182 -8 | 7.5 +1.3 | 97 -1.3 | close | 4 Ω vs 8 Ω: amp load changes | + |
| PHL Audio 5050 | 38 +3 | 0.254 = | 180 -10 | 5.9 -0.3 | 99.2 +0.9 | close | Xmax 5.9 mm < 6.2 mm: lower excursion-limited SPL | + |
| DAS Audio 15G | 35 = | 0.259 +0.01 | 225 +35 | 6 -0.2 | 98.8 +0.5 | close | Xmax 6 mm < 6.2 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 5052 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.