PHL Audio 4540 vp essais
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 45.8 Hz |
| Qts | 0.456 |
| Qes | 0.558 |
| Qms | 2.49 |
| Vas | 87.8 L |
| Sd | 535 cm² |
| Xmax | 6 mm |
| Re | 6.32 Ω |
| Bl | 13.4 T·m |
| Mms | 55.3 g |
| Pe | 300 W |
| Sensibilité | 94.8 dB |
Indication d'alignement
| EBP | 82 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 62.5 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma SM212 vp Nº1 | 45.8 = | 0.456 = | 87.1 -0.7 | 6.5 +0.5 | 94.8 = | close | + | |
| PHL Audio 4530 vp2 | 45.8 = | 0.454 = | 86.8 -1 | 6 = | 95 +0.2 | close | + | |
| PHL Audio 4530 vp clio p | 47.1 +1.3 | 0.46 = | 93.2 +5.4 | 6 = | 95.7 +0.9 | close | + | |
| Davis 31TCA12 vp 2018 CLIO POCKET | 45.8 = | 0.455 = | 86.8 -1 | 5 -1 | 95 +0.2 | close | 200 W vs 300 W: lower power handling · Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| DAS Audio 12P | 46.2 +0.4 | 0.459 = | 73.6 -14.2 | 6 = | 94.6 -0.2 | close | + | |
| Faital PRO 12FE300 | 47 +1.2 | 0.44 -0.02 | 81.4 -6.4 | 5.47 -0.53 | 95 +0.2 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 5.47 mm < 6 mm: lower excursion-limited SPL | + |
| PHL Audio 4530 vp | 45.8 = | 0.45 -0.01 | 104.5 +16.7 | 6 = | 95.8 +1 | close | + | |
| Radian 5212-8 | 45.1 -0.7 | 0.489 +0.03 | 87.9 +0.1 | 5 -1 | 94.7 -0.1 | close | Xmax 5 mm < 6 mm: lower excursion-limited SPL | + |
| Audax 330 vp | 45.8 = | 0.454 = | 86.8 -1 | 4.3 -1.7 | 95 +0.2 | close | 150 W vs 300 W: lower power handling · Xmax 4.3 mm < 6 mm: lower excursion-limited SPL | + |
| Beyma SM112/N v2012 | 43 -2.8 | 0.434 -0.02 | 94 +6.2 | 7.3 +1.3 | 95.3 +0.5 | close | + |
Comparer les 3 plus proches avec le 4540 vp essais →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.