Philips AD10240/W8
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 23 Hz |
| Qts | 0.261 |
| Qes | 0.27 |
| Qms | 7.86 |
| Vas | 248.2 L |
| Sd | 344 cm² |
| Xmax | 7.8 mm |
| Re | 6.2 Ω |
| Bl | 10.3 T·m |
| Mms | 32 g |
| Pe | 60 W |
| Sensibilité | 93.6 dB |
Indication d'alignement
| EBP | 85 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 39.1 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Focal 10L 6411 | 22.4 -0.6 | 0.253 -0.01 | 210.4 -37.8 | 8 +0.2 | 93.5 -0.1 | close | + | |
| Monacor SPH-250CTC vp CARBON | 20 -3 | 0.247 -0.01 | 220 -28.2 | 7.5 -0.3 | 94 +0.4 | close | 4 Ω vs 8 Ω: amp load changes · Xmax 7.5 mm < 7.8 mm: lower excursion-limited SPL | + |
| Aurum Cantus AC250/75C2C | 23 = | 0.275 +0.01 | 193 -55.2 | 8 +0.2 | 91.2 -2.4 | close | + | |
| SEAS CA26RE4X vp2 | 24.8 +1.8 | 0.273 +0.01 | 178 -70.2 | 7.6 -0.2 | 92.9 -0.7 | usable | Xmax 7.6 mm < 7.8 mm: lower excursion-limited SPL | + |
| Focal 10K 617 | 25.1 +2.1 | 0.242 -0.02 | 238 -10.2 | 6 -1.8 | 95.8 +2.2 | usable | Xmax 6 mm < 7.8 mm: lower excursion-limited SPL | + |
| Audax HD24S34HSMC | 24 +1 | 0.259 = | 253.2 +5 | 4 -3.8 | 93.9 +0.3 | usable | Xmax 4 mm < 7.8 mm: lower excursion-limited SPL | + |
| Ciare HS250 | 19 -4 | 0.242 -0.02 | 194 -54.2 | 8 +0.2 | 93.6 = | usable | 4 Ω vs 8 Ω: amp load changes | + |
| Aurum Cantus AC250F1 | 20 -3 | 0.287 +0.03 | 224 -24.2 | 8 +0.2 | 90 -3.6 | usable | + | |
| Accuton S280-6-282 | 20 -3 | 0.263 = | 226 -22.2 | 6 -1.8 | 90.9 -2.7 | usable | Xmax 6 mm < 7.8 mm: lower excursion-limited SPL | + |
| Vifa 25WP250 | 24 +1 | 0.298 +0.04 | 178 -70.2 | 8 +0.2 | 92.6 -1 | usable | + |
Comparer les 3 plus proches avec le AD10240/W8 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.