Peavey LOW RIDER 18
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 28.9 Hz |
| Qts | 0.429 |
| Qes | 0.45 |
| Qms | 9.07 |
| Vas | 288 L |
| Sd | 1340 cm² |
| Xmax | 9.6 mm |
| Re | 6.15 Ω |
| Bl | 22.17 T·m |
| Mms | 198.2 g |
| Pe | 800 W |
| Sensibilité | 93.7 dB |
Indication d'alignement
| EBP | 64 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 167.8 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| P.Audio E-18ELF | 30 +1.1 | 0.44 +0.01 | 263.57 -24.43 | 7.5 -2.1 | 93.6 -0.1 | close | Xmax 7.5 mm < 9.6 mm: lower excursion-limited SPL | + |
| Dayton Audio APOLLO 18F | 32 +3.1 | 0.401 -0.03 | 287.7 -0.3 | 10.6 +1 | 96.4 +2.7 | close | + | |
| Beyma 18G550 (prodance) | 29.5 +0.6 | 0.382 -0.05 | 291 +3 | 9 -0.6 | 96.7 +3 | close | Xmax 9 mm < 9.6 mm: lower excursion-limited SPL | + |
| SB Audience ROSSO-18SW650 | 31 +2.1 | 0.418 -0.01 | 304.3 +16.3 | 9 -0.6 | 97.2 +3.5 | close | Xmax 9 mm < 9.6 mm: lower excursion-limited SPL | + |
| Beyma 18PWB1000/FE | 31 +2.1 | 0.426 = | 220 -68 | 9.6 = | 94.9 +1.2 | close | + | |
| AER SB 18 | 26 -2.9 | 0.383 -0.05 | 288 = | 8.3 -1.3 | 94.5 +0.8 | close | 500 W vs 800 W: lower power handling · Xmax 8.3 mm < 9.6 mm: lower excursion-limited SPL | + |
| Magnat AGRESSOR 5000 | 24 -4.9 | 0.431 = | 324 +36 | 10.6 +1 | 95.3 +1.6 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Sica 18 PFS 4 | 28.7 -0.2 | 0.37 -0.06 | 245.9 -42.1 | 9.5 -0.1 | 95.1 +1.4 | close | Xmax 9.5 mm < 9.6 mm: lower excursion-limited SPL | + |
| Beyma 18PWB1000/FE v2016 | 27 -1.9 | 0.381 -0.05 | 317 +29 | 11.7 +2.1 | 95.2 +1.5 | close | + | |
| McCauley 6152-8 | 30 +1.1 | 0.434 +0.01 | 354 +66 | 12 +2.4 | 97.1 +3.4 | close | + |
Comparer les 3 plus proches avec le LOW RIDER 18 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.