Peavey 1508-8 SPS BWX
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 41.9 Hz |
| Qts | 0.438 |
| Qes | 0.457 |
| Qms | 10.357 |
| Vas | 185.9 L |
| Sd | 840 cm² |
| Xmax | 4.7 mm |
| Re | 5.27 Ω |
| Bl | 15.3 T·m |
| Mms | 76.8 g |
| Pe | 500 W |
| Sensibilité | 98.6 dB |
Indication d'alignement
| EBP | 92 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 115.7 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fane SOVEREIGN 15-425 | 43 +1.1 | 0.417 -0.02 | 180.6 -5.3 | 4.6 -0.1 | 98.5 -0.1 | close | Xmax 4.6 mm < 4.7 mm: lower excursion-limited SPL | + |
| B&C 15 FCX 76 | 40 -1.9 | 0.445 +0.01 | 187 +1.1 | 6.5 +1.8 | 97.9 -0.7 | close | + | |
| Beyma SM115 | 42 +0.1 | 0.405 -0.03 | 185 -0.9 | 6.7 +2 | 98.2 -0.4 | close | + | |
| SICA 15 BP 3 SL | 41.9 = | 0.419 -0.02 | 191.6 +5.7 | 4 -0.7 | 98.7 +0.1 | close | 350 W vs 500 W: lower power handling · Xmax 4 mm < 4.7 mm: lower excursion-limited SPL | + |
| SICA P-A-SL15B3P | 41.9 = | 0.419 -0.02 | 191.6 +5.7 | 4 -0.7 | 98.7 +0.1 | close | 350 W vs 500 W: lower power handling · Xmax 4 mm < 4.7 mm: lower excursion-limited SPL | + |
| Beyma 15CXA400Fe | 40 -1.9 | 0.419 -0.02 | 191 +5.1 | 6 +1.3 | 97.6 -1 | close | + | |
| B&C 15 CX 40 | 44 +2.1 | 0.43 -0.01 | 162 -23.9 | 4.5 -0.2 | 98.7 +0.1 | close | Xmax 4.5 mm < 4.7 mm: lower excursion-limited SPL | + |
| P.Audio R15/64W | 41.1 -0.8 | 0.452 +0.01 | 172.2 -13.7 | 5 +0.3 | 96.7 -1.9 | close | 250 W vs 500 W: lower power handling | + |
| Selenium 15PW5 | 40 -1.9 | 0.4 -0.04 | 190 +4.1 | 5.7 +1 | 98.3 -0.3 | close | 350 W vs 500 W: lower power handling | + |
| 18 Sound 15W750 | 40 -1.9 | 0.42 -0.02 | 182 -3.9 | 8 +3.3 | 98 -0.6 | close | 16 Ω vs 8 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 1508-8 SPS BWX →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.