Peavey 1501-4 DT v1993
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 4 Ω |
| Fs | 46 Hz |
| Qts | 0.343 |
| Qes | 0.4 |
| Qms | 2.4 |
| Vas | 188 L |
| Sd | 800 cm² |
| Xmax | 1 mm |
| Re | 3.2 Ω |
| Bl | 11.5 T·m |
| Mms | 57.1 g |
| Pe | 250 W |
| Sensibilité | 102.6 dB |
Indication d'alignement
| EBP | 115 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 57.8 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Peavey 1505 KADT | 44.3 -1.7 | 0.354 +0.01 | 187 -1 | 0.9 -0.1 | 100.2 -2.4 | close | 8 Ω vs 4 Ω: amp load changes · Xmax 0.9 mm < 1 mm: lower excursion-limited SPL | + |
| Peavey 1502-4DT | 43.1 -2.9 | 0.363 +0.02 | 192 +4 | 2.8 +1.8 | 102 -0.6 | close | + | |
| P.Audio 15BM-200B | 42.9 -3.1 | 0.325 -0.02 | 188 = | 1.5 +0.5 | 99.5 -3.1 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Fane STUDIO 15L | 45 -1 | 0.338 -0.01 | 190 +2 | 4.3 +3.3 | 100.6 -2 | close | 8 Ω vs 4 Ω: amp load changes | + |
| P.Audio SN-15MB | 47 +1 | 0.329 -0.01 | 176.8 -11.2 | 3.3 +2.3 | 101.1 -1.5 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Jensen NEO 15-300 | 42.8 -3.2 | 0.34 = | 194.3 +6.3 | 2.5 +1.5 | 99.2 -3.4 | close | 8 Ω vs 4 Ω: amp load changes | + |
| Peavey 1505-4 DT v1993 | 44.6 -1.4 | 0.373 +0.03 | 182 -6 | 5.1 +4.1 | 102.1 -0.5 | usable | + | |
| JBL G135-8 | 45 -1 | 0.355 +0.01 | 235 +47 | 2.5 +1.5 | 101.4 -1.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| Audax PR38LEX100VST vp CBM | 42 -4 | 0.343 = | 195 +7 | 3.5 +2.5 | 99.4 -3.2 | usable | 8 Ω vs 4 Ω: amp load changes | + |
| RCF L 15/864K | 50 +4 | 0.329 -0.01 | 170 -18 | 4 +3 | 101.8 -0.8 | usable | 8 Ω vs 4 Ω: amp load changes | + |
Comparer les 3 plus proches avec le 1501-4 DT v1993 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.