Peavey 15 PRO RIDER CU CP SUBWOOFER
Paramètres Thiele-Small
| Taille nominale | 15" |
|---|---|
| Impédance | 8 Ω |
| Fs | 34.8 Hz |
| Qts | 0.236 |
| Qes | 0.242 |
| Qms | 8.78 |
| Vas | 208 L |
| Sd | 840 cm² |
| Xmax | 4.6 mm |
| Re | 5.7 Ω |
| Bl | 22.6 T·m |
| Mms | 99.5 g |
| Pe | 600 W |
| Sensibilité | 99 dB |
Indication d'alignement
| EBP | 144 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 26.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| HH Electronics 1501E | 36 +1.2 | 0.238 = | 190.5 -17.5 | 4.5 -0.1 | 99 = | close | 200 W vs 600 W: lower power handling · Xmax 4.5 mm < 4.6 mm: lower excursion-limited SPL | + |
| Celestion NTR15-3018E v2015 | 34.6 -0.2 | 0.245 +0.01 | 225.7 +17.7 | 5 +0.4 | 99.1 +0.1 | close | 450 W vs 600 W: lower power handling | + |
| RCF L 15/544K | 35 +0.2 | 0.233 = | 227 +19 | 4 -0.6 | 98.9 -0.1 | close | 400 W vs 600 W: lower power handling · Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
| Celestion NTR15-3018E | 35 +0.2 | 0.261 +0.03 | 223.5 +15.5 | 5 +0.4 | 99.2 +0.2 | close | 450 W vs 600 W: lower power handling | + |
| RCF L 15/554K | 35 +0.2 | 0.243 +0.01 | 227 +19 | 8 +3.4 | 98.7 -0.3 | close | + | |
| PHL Audio 5010 | 34 -0.8 | 0.25 +0.01 | 200 -8 | 6.4 +1.8 | 98.2 -0.8 | close | + | |
| Celestion FTR15-4080F-Bis | 35 +0.2 | 0.243 +0.01 | 182.8 -25.2 | 6 +1.4 | 98.3 -0.7 | close | + | |
| PHL Audio 5051 | 37 +2.2 | 0.245 +0.01 | 190 -18 | 5.9 +1.3 | 99.2 +0.2 | close | + | |
| DAS Audio 15G | 35 +0.2 | 0.259 +0.02 | 225 +17 | 6 +1.4 | 98.8 -0.2 | close | + | |
| Audax PR38S100VST | 33 -1.8 | 0.236 = | 218.1 +10.1 | 4 -0.6 | 97.8 -1.2 | close | 200 W vs 600 W: lower power handling · Xmax 4 mm < 4.6 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 15 PRO RIDER CU CP SUBWOOFER →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.