Peavey 1203-8 v1993
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 59.4 Hz |
| Qts | 0.381 |
| Qes | 0.4 |
| Qms | 8.1 |
| Vas | 69 L |
| Sd | 515 cm² |
| Xmax | 1 mm |
| Re | 6.1 Ω |
| Bl | 14.8 T·m |
| Mms | 38.7 g |
| Pe | 350 W |
| Sensibilité | 98.7 dB |
Indication d'alignement
| EBP | 149 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 28.2 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Fostex 12w150 | 60 +0.6 | 0.411 +0.03 | 74 +5 | 1.2 +0.2 | 98.9 +0.2 | close | 60 W vs 350 W: lower power handling | + |
| Peavey 1203-4 v1993 | 57.8 -1.6 | 0.371 -0.01 | 72 +3 | 1 = | 101.8 +3.1 | close | 4 Ω vs 8 Ω: amp load changes | + |
| LaVoce FSF122.02 | 57 -2.4 | 0.374 -0.01 | 69.5 +0.5 | 3 +2 | 98.4 -0.3 | close | 150 W vs 350 W: lower power handling | + |
| Celestion TF 1218TC | 56 -3.4 | 0.408 +0.03 | 80.2 +11.2 | 1.5 +0.5 | 98.4 -0.3 | close | 100 W vs 350 W: lower power handling | + |
| Celestion TF 1218TC v2008 | 56 -3.4 | 0.408 +0.03 | 80.2 +11.2 | 1.5 +0.5 | 98.4 -0.3 | close | 100 W vs 350 W: lower power handling | + |
| Celestion TF1220 | 55.8 -3.6 | 0.389 +0.01 | 72.79 +3.79 | 2 +1 | 96.4 -2.3 | close | 150 W vs 350 W: lower power handling | + |
| Fertin Acoustics LB 31 SONO | 59.5 +0.1 | 0.407 +0.03 | 70 +1 | 4 +3 | 97.5 -1.2 | close | 200 W vs 350 W: lower power handling | + |
| Beyma SM112 vp | 57.8 -1.6 | 0.391 +0.01 | 64.6 -4.4 | 4.2 +3.2 | 97.7 -1 | close | 250 W vs 350 W: lower power handling | + |
| Peerless FSL-1225R02-08 | 59 -0.4 | 0.407 +0.03 | 59.4 -9.6 | 2.5 +1.5 | 98 -0.7 | close | + | |
| RCF L 12/568H | 58 -1.4 | 0.409 +0.03 | 72 +3 | 4 +3 | 98.1 -0.6 | close | 200 W vs 350 W: lower power handling | + |
Comparer les 3 plus proches avec le 1203-8 v1993 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.