Precision Devices PD188
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 37.409 Hz |
| Qts | 0.28 |
| Qes | 0.289 |
| Qms | 8.406 |
| Vas | 224.419 L |
| Sd | 1134.11 cm² |
| Xmax | 9.5 mm |
| Re | 5.58 Ω |
| Bl | 26.591 T·m |
| Mms | 146.613 g |
| Pe | 600 W |
| Sensibilité | 98.5 dB |
Indication d'alignement
| EBP | 129 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 41.7 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Monacor SP-18/1000HP | 35 -2.41 | 0.282 = | 219 -5.42 | 7.9 -1.6 | 98.8 +0.3 | close | Xmax 7.9 mm < 9.5 mm: lower excursion-limited SPL | + |
| Faital PRO 18HP1010 | 35 -2.41 | 0.31 +0.03 | 225.9 +1.48 | 9.75 +0.25 | 98 -0.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
| PHL Audio 7321ND | 33 -4.41 | 0.278 = | 230 +5.58 | 8.5 -1 | 98.3 -0.2 | close | Xmax 8.5 mm < 9.5 mm: lower excursion-limited SPL | + |
| 18 Sound 18LW2400 | 35 -2.41 | 0.31 +0.03 | 230 +5.58 | 9.5 = | 98 -0.5 | close | + | |
| Beyma 18PW1400/FE | 32 -5.41 | 0.273 -0.01 | 228.9 +4.48 | 9.1 -0.4 | 98.3 -0.2 | close | Xmax 9.1 mm < 9.5 mm: lower excursion-limited SPL | + |
| Oberton 18FBR700 | 35.56 -1.85 | 0.271 -0.01 | 231.3 +6.88 | 8 -1.5 | 98 -0.5 | close | Xmax 8 mm < 9.5 mm: lower excursion-limited SPL | + |
| PD PD 185N002 | 36 -1.41 | 0.297 +0.02 | 226 +1.58 | 7.8 -1.7 | 98.7 +0.2 | close | Xmax 7.8 mm < 9.5 mm: lower excursion-limited SPL | + |
| Precision Devices PD 185N002 | 36 -1.41 | 0.297 +0.02 | 226 +1.58 | 7.8 -1.7 | 98.7 +0.2 | close | Xmax 7.8 mm < 9.5 mm: lower excursion-limited SPL | + |
| Faital PRO 18HP1022 | 35 -2.41 | 0.3 +0.02 | 204.9 -19.52 | 9.5 = | 98 -0.5 | close | + | |
| Beyma 18PW1400FE /S | 32 -5.41 | 0.27 -0.01 | 228.9 +4.48 | 10 +0.5 | 98 -0.5 | close | + |
Comparer les 3 plus proches avec le PD188 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.