PD 184C002
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 40 Hz |
| Qts | 0.339 |
| Qes | 0.36 |
| Qms | 5.67 |
| Vas | 268 L |
| Sd | 1152 cm² |
| Xmax | 8.5 mm |
| Re | 5.2 Ω |
| Bl | 20 T·m |
| Mms | 109.9 g |
| Pe | 900 W |
| Sensibilité | 100.6 dB |
Indication d'alignement
| EBP | 111 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 80 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Precision Devices 184C002 | 40 = | 0.339 = | 268 = | 8.5 = | 100.6 = | close | + | |
| RCF LF 18H400 | 38 -2 | 0.321 -0.02 | 250 -18 | 7.4 -1.1 | 100.3 -0.3 | close | Xmax 7.4 mm < 8.5 mm: lower excursion-limited SPL | + |
| PHL Audio 7050 | 36 -4 | 0.369 +0.03 | 260 -8 | 7.5 -1 | 99.3 -1.3 | close | Xmax 7.5 mm < 8.5 mm: lower excursion-limited SPL | + |
| Fane SOVEREIGN PRO 18-800P | 34.5 -5.5 | 0.338 = | 264 -4 | 7.5 -1 | 97.6 -3 | close | Xmax 7.5 mm < 8.5 mm: lower excursion-limited SPL | + |
| 18 Sound 18W1300 | 35 -5 | 0.33 -0.01 | 336 +68 | 8.5 = | 99.5 -1.1 | close | + | |
| Fane COLOSSUS 18XB | 36 -4 | 0.323 -0.02 | 246 -22 | 7.5 -1 | 98.5 -2.1 | close | Xmax 7.5 mm < 8.5 mm: lower excursion-limited SPL | + |
| Fane Colossus 18SB | 36 -4 | 0.346 +0.01 | 199 -69 | 8.25 -0.25 | 100 -0.6 | close | Xmax 8.25 mm < 8.5 mm: lower excursion-limited SPL | + |
| Peavey LO MAX 18 v2011 | 33.5 -6.5 | 0.321 -0.02 | 294.4 +26.4 | 10.2 +1.7 | 98.9 -1.7 | usable | + | |
| 18 Sound 18LW1250 | 35 -5 | 0.271 -0.07 | 268 = | 8.7 +0.2 | 100.2 -0.4 | usable | + | |
| PHL Audio 7090 | 36 -4 | 0.386 +0.05 | 260 -8 | 8 -0.5 | 98.2 -2.4 | usable | Xmax 8 mm < 8.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le 184C002 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.