Paramètres Thiele-Small
| Taille nominale | 6.5" |
|---|---|
| Impédance | 8 Ω |
| Fs | 62.32 Hz |
| Qts | 0.28 |
| Qes | 0.296 |
| Qms | 5.22 |
| Vas | 9.3 L |
| Sd | 127 cm² |
| Xmax | 5.5 mm |
| Re | 5.57 Ω |
| Bl | 10.77 T·m |
| Mms | 15.72 g |
| Pe | 150 W |
| Sensibilité | 92 dB |
Indication d'alignement
| EBP | 211 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 1.7 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Beyma 6"P200/ND | 56 -6.32 | 0.29 +0.01 | 11.9 +2.6 | 5.5 = | 92 = | close | + | |
| 18 Sound 6ND430 | 61 -1.32 | 0.27 -0.01 | 12.6 +3.3 | 5 -0.5 | 92.5 +0.5 | close | Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| Beyma 6P200Fe | 58 -4.32 | 0.26 -0.02 | 11.1 +1.8 | 5 -0.5 | 93 +1 | close | Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| B&C 6PS38 | 75 +12.68 | 0.3 +0.02 | 8 -1.3 | 6 +0.5 | 94 +2 | usable | + | |
| 18 Sound 6ND430 | 64 +1.68 | 0.24 -0.04 | 12.2 +2.9 | 5 -0.5 | 92.5 +0.5 | usable | 4 Ω vs 8 Ω: amp load changes · Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| 18 Sound 6ND430 | 66 +3.68 | 0.3 +0.02 | 12.6 +3.3 | 5 -0.5 | 94 +2 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 5 mm < 5.5 mm: lower excursion-limited SPL | + |
| Oberton 6B150 | 55.04 -7.28 | 0.292 +0.01 | 14.61 +5.31 | 5.5 = | 92 = | usable | + | |
| Beyma 6P200Fe | 66 +3.68 | 0.35 +0.07 | 8.8 -0.5 | 4 -1.5 | 93 +1 | usable | 16 Ω vs 8 Ω: amp load changes · Xmax 4 mm < 5.5 mm: lower excursion-limited SPL | + |
| B&C 6PS44 | 71 +8.68 | 0.33 +0.05 | 7 -2.3 | 4.5 -1 | 93 +1 | usable | Xmax 4.5 mm < 5.5 mm: lower excursion-limited SPL | + |
| B&C 6NDL38 | 69 +6.68 | 0.39 +0.11 | 7.1 -2.2 | 6 +0.5 | 91 -1 | usable | 4 Ω vs 8 Ω: amp load changes | + |