Oberton 18XB1201
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 38.05 Hz |
| Qts | 0.317 |
| Qes | 0.332 |
| Qms | 6.92 |
| Vas | 159.37 L |
| Sd | 1158 cm² |
| Xmax | 10.5 mm |
| Re | 5.25 Ω |
| Bl | 26.71 T·m |
| Mms | 188.94 g |
| Pe | 1200 W |
| Sensibilité | 98.5 dB |
Indication d'alignement
| EBP | 115 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 40.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Oberton 18NXB700 | 36.24 -1.81 | 0.312 -0.01 | 155.46 -3.91 | 9 -1.5 | 98 -0.5 | close | Xmax 9 mm < 10.5 mm: lower excursion-limited SPL | + |
| Faital PRO 18HP1030 | 35 -3.05 | 0.32 = | 172.2 +12.83 | 12.45 +1.95 | 98 -0.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
| Oberton 18XB1301DS | 35.7 -2.35 | 0.302 -0.02 | 172.9 +13.53 | 12 +1.5 | 97.5 -1 | close | + | |
| Faital PRO 18HP1060 | 35 -3.05 | 0.33 +0.01 | 184.4 +25.03 | 12.45 +1.95 | 98 -0.5 | close | 4 Ω vs 8 Ω: amp load changes | + |
| 18 Sound 18NLW4500 | 35 -3.05 | 0.33 +0.01 | 151 -8.37 | 15.3 +4.8 | 97 -1.5 | close | + | |
| LaVoce SAF184.50 | 35 -3.05 | 0.329 +0.01 | 162 +2.63 | 9.2 -1.3 | 96.5 -2 | close | Xmax 9.2 mm < 10.5 mm: lower excursion-limited SPL | + |
| PD PD 1845-1N | 34.1 -3.95 | 0.323 +0.01 | 176 +16.63 | 9.5 -1 | 97.5 -1 | close | Xmax 9.5 mm < 10.5 mm: lower excursion-limited SPL | + |
| Precision Devices PD 1845-1N | 34.1 -3.95 | 0.323 +0.01 | 176 +16.63 | 9.5 -1 | 97.5 -1 | close | Xmax 9.5 mm < 10.5 mm: lower excursion-limited SPL | + |
| Oberton 18XB700 | 36.1 -1.95 | 0.304 -0.01 | 183.22 +23.85 | 9 -1.5 | 98 -0.5 | close | Xmax 9 mm < 10.5 mm: lower excursion-limited SPL | + |
| B&C 18DS100 | 34 -4.05 | 0.29 -0.03 | 155 -4.37 | 14.5 +4 | 97.5 -1 | close | + |
Comparer les 3 plus proches avec le 18XB1201 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.