← tous les HP

MTX Audio BG104A

10" · 4 Ω · 250 W · 91.1 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale10"
Impédance4 Ω
Fs26 Hz
Qts0.359
Qes0.38
Qms6.55
Vas72.8 L
Sd355.8 cm²
Xmax9.7 mm
Re3.33 Ω
Bl11.4 T·m
Mms91.4 g
Pe250 W
Sensibilité91.1 dB

Indication d'alignement

EBP68 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 25.3 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Wavecor WF275BD0127 +10.368 +0.0181.5 +8.79 -0.792.4 +1.3close180 W vs 250 W: lower power handling · Xmax 9 mm < 9.7 mm: lower excursion-limited SPL+
Image Dynamics IDQ10DQV325.5 -0.50.384 +0.0371 -1.89 -0.788.9 -2.2close8 Ω vs 4 Ω: amp load changes · Xmax 9 mm < 9.7 mm: lower excursion-limited SPL+
SB Acoustics SB29NRX75-826 =0.37 +0.0185.6 +12.811 +1.389 -2.1close8 Ω vs 4 Ω: amp load changes+
Volt RV255028 +20.331 -0.0371.8 -19.1 -0.689.5 -1.6close8 Ω vs 4 Ω: amp load changes · Xmax 9.1 mm < 9.7 mm: lower excursion-limited SPL+
JBL P100030 +40.382 +0.0271 -1.87.8 -1.991.2 +0.1close8 Ω vs 4 Ω: amp load changes · Xmax 7.8 mm < 9.7 mm: lower excursion-limited SPL+
Peerless 83084624.3 -1.70.328 -0.0381.8 +98.7 -192.2 +1.1close175 W vs 250 W: lower power handling · Xmax 8.7 mm < 9.7 mm: lower excursion-limited SPL+
Tang Band WT-644F32 +60.357 =77 +4.27.9 -1.891.3 +0.2close8 Ω vs 4 Ω: amp load changes · 180 W vs 250 W: lower power handling · Xmax 7.9 mm < 9.7 mm: lower excursion-limited SPL+
STX W.27.500.8.FCX25 -10.352 -0.0159 -13.89.6 -0.187.6 -3.5close8 Ω vs 4 Ω: amp load changes · Xmax 9.6 mm < 9.7 mm: lower excursion-limited SPL+
JBL SB21025.4 -0.60.412 +0.0573 +0.27.5 -2.289.8 -1.3closeXmax 7.5 mm < 9.7 mm: lower excursion-limited SPL+
Vifa NE-265W-0423 -30.294 -0.0672.8 =8.9 -0.891.1 =close190 W vs 250 W: lower power handling · Xmax 8.9 mm < 9.7 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le BG104A →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.