Monacor SPH-250KE
Paramètres Thiele-Small
| Taille nominale | 10" |
|---|---|
| Impédance | 8 Ω |
| Fs | 23 Hz |
| Qts | 0.414 |
| Qes | 0.45 |
| Qms | 5.25 |
| Vas | 204 L |
| Sd | 346 cm² |
| Xmax | 4.8 mm |
| Re | 6.1 Ω |
| Bl | 8.8 T·m |
| Mms | 39.4 g |
| Pe | 100 W |
| Sensibilité | 90.6 dB |
Indication d'alignement
| EBP | 51 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 106.4 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Audax HD24S45TSM-C-4CA14 | 23 = | 0.421 +0.01 | 190 -14 | 4 -0.8 | 89.9 -0.7 | close | Xmax 4 mm < 4.8 mm: lower excursion-limited SPL | + |
| Aurum Cantus AC250MK2 | 23 = | 0.423 +0.01 | 235 +31 | 8 +3.2 | 90.2 -0.4 | close | + | |
| Focal 10V 516J | 22.3 -0.7 | 0.39 -0.02 | 180 -24 | 7.5 +2.7 | 90.7 +0.1 | close | + | |
| Aurum Cantus AC250F1D | 23 = | 0.444 +0.03 | 184 -20 | 8 +3.2 | 92 +1.4 | close | 4 Ω vs 8 Ω: amp load changes | + |
| JBL 127H | 25 +2 | 0.433 +0.02 | 237.9 +33.9 | 4.8 = | 91.9 +1.3 | close | 50 W vs 100 W: lower power handling | + |
| Scan-Speak 25W/8565-00 | 20 -3 | 0.407 -0.01 | 229 +25 | 6.5 +1.7 | 89.8 -0.8 | close | + | |
| Scan-Speak 26W/8534G00 v2011 | 23 = | 0.402 -0.01 | 150 -54 | 6 +1.2 | 89.8 -0.8 | close | + | |
| SEAS A26RE4 - H1411 | 25 +2 | 0.415 = | 161 -43 | 4 -0.8 | 90.6 = | close | Xmax 4 mm < 4.8 mm: lower excursion-limited SPL | + |
| KEF B139 SP1044 | 25 +2 | 0.373 -0.04 | 164 -40 | 6 +1.2 | 90.9 +0.3 | usable | 50 W vs 100 W: lower power handling | + |
| Audax HT240M0 vp1 | 27.5 +4.5 | 0.404 -0.01 | 172 -32 | 4.5 -0.3 | 91.7 +1.1 | usable | Xmax 4.5 mm < 4.8 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le SPH-250KE →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.