Monacor SPH-200TC bobines en série
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 16 Ω |
| Fs | 28 Hz |
| Qts | 0.239 |
| Qes | 0.249 |
| Qms | 6.19 |
| Vas | 65 L |
| Sd | 420 cm² |
| Xmax | 2.9 mm |
| Re | 13.6 Ω |
| Bl | 34.4 T·m |
| Mms | 122.9 g |
| Pe | 60 W |
| Sensibilité | 87.3 dB |
Indication d'alignement
| EBP | 112 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 8.4 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Helix P12W PRECISION | 27 -1 | 0.25 +0.01 | 72 +7 | 8.5 +5.6 | 89 +1.7 | close | 4 Ω vs 16 Ω: amp load changes | + |
| Mivoc AWM 124 | 30 +2 | 0.251 +0.01 | 68 +3 | 4.7 +1.8 | 94.6 +7.3 | usable | 4 Ω vs 16 Ω: amp load changes | + |
| Alcone AC 12 SW-8 | 25.7 -2.3 | 0.224 -0.01 | 84.4 +19.4 | 4 +1.1 | 90.9 +3.6 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| BMS 12S330 v2016 | 28.6 +0.6 | 0.24 = | 85.5 +20.5 | 8 +5.1 | 92.3 +5 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Celestion FTR12-4080DL | 28.9 +0.9 | 0.303 +0.06 | 68.6 +3.6 | 8.7 +5.8 | 89.9 +2.6 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Artech SPM-303 | 30 +2 | 0.243 = | 95 +30 | 3.6 +0.7 | 92.3 +5 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| Raveland BSW 124-II | 28 = | 0.252 +0.01 | 91.4 +26.4 | 5.4 +2.5 | 94.7 +7.4 | usable | 4 Ω vs 16 Ω: amp load changes | + |
| BMS 12S330 v2018 | 28.6 +0.6 | 0.295 +0.06 | 81.4 +16.4 | 8 +5.1 | 91.1 +3.8 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| BMS 12S330 | 28.6 +0.6 | 0.24 = | 85.5 +20.5 | 8 +5.1 | 96 +8.7 | usable | 8 Ω vs 16 Ω: amp load changes | + |
| HiVi M12 8 Ohms | 27 -1 | 0.335 +0.1 | 81.4 +16.4 | 5.2 +2.3 | 89.4 +2.1 | usable | 8 Ω vs 16 Ω: amp load changes | + |
Comparer les 3 plus proches avec le SPH-200TC bobines en série →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.