Monacor SP-305PA
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 35 Hz |
| Qts | 0.283 |
| Qes | 0.3 |
| Qms | 4.95 |
| Vas | 315 L |
| Sd | 495 cm² |
| Xmax | 5.3 mm |
| Re | 6 Ω |
| Bl | 10 T·m |
| Mms | 22.5 g |
| Pe | 175 W |
| Sensibilité | 99.8 dB |
Indication d'alignement
| EBP | 117 · ported |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 60.1 L |
EBP > 100 : favorise un alignement bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Supravox 285 GMF vp deadharo | 37.9 +2.9 | 0.278 = | 263 -52 | 4 -1.3 | 100.3 +0.5 | usable | 70 W vs 175 W: lower power handling · Xmax 4 mm < 5.3 mm: lower excursion-limited SPL | + |
| Davis 31TCA12W | 27 -8 | 0.283 = | 335 +20 | 6 +0.7 | 96.2 -3.6 | usable | + | |
| Crites Speakers CW1228 | 27.7 -7.3 | 0.277 -0.01 | 286.6 -28.4 | 6.4 +1.1 | 96.3 -3.5 | usable | 120 W vs 175 W: lower power handling | + |
| Davis 31TK12 | 38.1 +3.1 | 0.314 +0.03 | 216 -99 | 5 -0.3 | 98 -1.8 | usable | Xmax 5 mm < 5.3 mm: lower excursion-limited SPL | + |
| Beyma SM212 | 34 -1 | 0.258 -0.02 | 198 -117 | 8.2 +2.9 | 98 -1.8 | usable | + | |
| Davis 31TCA12 v2009 | 32.5 -2.5 | 0.31 +0.03 | 222 -93 | 6 +0.7 | 95.9 -3.9 | usable | + | |
| Davis 31TCA12 vp rc | 32.5 -2.5 | 0.314 +0.03 | 222 -93 | 6 +0.7 | 96.2 -3.6 | usable | + | |
| Audax HD33S66 vp | 28.8 -6.2 | 0.272 -0.01 | 441.3 +126.3 | 9.9 +4.6 | 98.5 -1.3 | usable | + | |
| Davis 31TCA12 v2012 | 38 +3 | 0.333 +0.05 | 216 -99 | 6 +0.7 | 97.9 -1.9 | usable | + | |
| Goodmans AXIOM 301 vp | 36.4 +1.4 | 0.277 -0.01 | 234.1 -80.9 | 3.2 -2.1 | 98 -1.8 | usable | 40 W vs 175 W: lower power handling · Xmax 3.2 mm < 5.3 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le SP-305PA →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.