Monacor SP-300GI
Paramètres Thiele-Small
| Taille nominale | 12" |
|---|---|
| Impédance | 8 Ω |
| Fs | 65 Hz |
| Qts | 0.969 |
| Qes | 1.28 |
| Qms | 3.99 |
| Vas | 75 L |
| Sd | 510 cm² |
| Xmax | 3.2 mm |
| Re | 6.5 Ω |
| Bl | 7.8 T·m |
| Mms | 29.1 g |
| Pe | 150 W |
| Sensibilité | 94.9 dB |
Indication d'alignement
| EBP | 51 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | Qts too high |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Mercuriale PTR 306 M0 | 58 -7 | 0.808 -0.16 | 70.1 -4.9 | 3.9 +0.7 | 94.6 -0.3 | usable | + | |
| Celestion TF 1215 | 62 -3 | 0.857 -0.11 | 69 -6 | 2.5 -0.7 | 96.2 +1.3 | usable | Xmax 2.5 mm < 3.2 mm: lower excursion-limited SPL | + |
| Fonestar FPW 350 | 52 -13 | 0.876 -0.09 | 65 -10 | 3.7 +0.5 | 91.8 -3.1 | usable | + | |
| SICA 12 D 1.5 CS 8 Ohms | 62 -3 | 0.748 -0.22 | 63.5 -11.5 | 2.7 -0.5 | 96.8 +1.9 | usable | 100 W vs 150 W: lower power handling · Xmax 2.7 mm < 3.2 mm: lower excursion-limited SPL | + |
| Sica 12 D 1.5 CS | 62 -3 | 0.75 -0.22 | 63.5 -11.5 | 2.7 -0.5 | 96.9 +2 | usable | Xmax 2.7 mm < 3.2 mm: lower excursion-limited SPL | + |
| Celestion F12M-150 Triple Cone | 69.4 +4.4 | 0.906 -0.06 | 46.9 -28.1 | 2.3 -0.9 | 95.2 +0.3 | usable | Xmax 2.3 mm < 3.2 mm: lower excursion-limited SPL | + |
| Elokance 12WF500 | 50 -15 | 1.102 +0.13 | 99.1 +24.1 | 3.6 +0.4 | 93.2 -1.7 | usable | + | |
| Siemens KL405 | 75.8 +10.8 | 0.77 -0.2 | 68 -7 | 3 -0.2 | 99.2 +4.3 | usable | Xmax 3 mm < 3.2 mm: lower excursion-limited SPL | + |
| Siare 31TE vp | 53.4 -11.6 | 0.746 -0.22 | 62 -13 | 4.1 +0.9 | 93.8 -1.1 | usable | + | |
| Supravox T285HF64 | 55 -10 | 0.6 -0.37 | 74.6 -0.4 | 3.3 +0.1 | 95.6 +0.7 | usable | 70 W vs 150 W: lower power handling | + |
Comparer les 3 plus proches avec le SP-300GI →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.