McCauley B1860
Paramètres Thiele-Small
| Taille nominale | 18" |
|---|---|
| Impédance | 8 Ω |
| Fs | 23.9 Hz |
| Qts | 0.244 |
| Qes | 0.25 |
| Qms | 9.49 |
| Vas | 723.6 L |
| Sd | 1283.2 cm² |
| Xmax | 5.5 mm |
| Re | 6.2 Ω |
| Bl | 23 T·m |
| Mms | 141.5 g |
| Pe | 400 W |
| Sensibilité | 99.1 dB |
Indication d'alignement
| EBP | 96 · flexible |
|---|---|
| Sealed Vb (Qtc ≈ 0.71) | ≈ 97.8 L |
EBP 50-100 : fonctionne en clos ou en bass-reflex.
Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.
Candidats de substitution
| HP | Fs (Hz) | Qts | Vas (L) | Xmax (mm) | Sens (dB) | Adéquation | Notes | Comparer |
|---|---|---|---|---|---|---|---|---|
| Altec 3184 | 24 +0.1 | 0.219 -0.02 | 690.9 -32.7 | 6.4 +0.9 | 98.5 -0.6 | close | 300 W vs 400 W: lower power handling | + |
| Great Plains Audio 3184 GPA | 24 +0.1 | 0.219 -0.02 | 690.9 -32.7 | 6.4 +0.9 | 98.5 -0.6 | close | 300 W vs 400 W: lower power handling | + |
| RCF LP 18/551 | 21.7 -2.2 | 0.222 -0.02 | 760 +36.4 | 10 +4.5 | 98.8 -0.3 | close | + | |
| Beyma 18GT200 v1 | 24.6 +0.7 | 0.213 -0.03 | 595 -128.6 | 5.8 +0.3 | 99.3 +0.2 | close | 250 W vs 400 W: lower power handling | + |
| Eminence 111712 | 21.6 -2.3 | 0.288 +0.04 | 736.2 +12.6 | 5.8 +0.3 | 97.1 -2 | close | + | |
| Electro-Voice DL18MT | 24 +0.1 | 0.269 +0.03 | 580.5 -143.1 | 5.59 +0.09 | 96.6 -2.5 | close | + | |
| JBL 2245H | 20 -3.9 | 0.24 = | 821.2 +97.6 | 8.5 +3 | 97.2 -1.9 | usable | 300 W vs 400 W: lower power handling | + |
| Monacor SP-495PA | 25 +1.1 | 0.286 +0.04 | 690 -33.6 | 4 -1.5 | 98.6 -0.5 | usable | 200 W vs 400 W: lower power handling · Xmax 4 mm < 5.5 mm: lower excursion-limited SPL | + |
| Eminence SIGMA PRO 18 A2 (prodance) | 26 +2.1 | 0.299 +0.05 | 613 -110.6 | 6.1 +0.6 | 98.3 -0.8 | usable | + | |
| Fertin Acoustics 46EX 07.5V | 22.2 -1.7 | 0.24 = | 667.7 -55.9 | 3 -2.5 | 98.6 -0.5 | usable | 100 W vs 400 W: lower power handling · Xmax 3 mm < 5.5 mm: lower excursion-limited SPL | + |
Comparer les 3 plus proches avec le B1860 →
Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.
Utilisé dans les caissons (0)
No enclosure in the catalog uses this driver yet.