← tous les HP

Magnat SUPREME 3800

15" · 4 Ω · 380 W · 97.3 dB · datasheet ↗

Paramètres Thiele-Small

Taille nominale15"
Impédance4 Ω
Fs25 Hz
Qts0.31
Qes0.33
Qms5.2
Vas271 L
Sd900 cm²
Xmax8.6 mm
Re3 Ω
Bl15.6 T·m
Mms169.8 g
Pe380 W
Sensibilité97.3 dB

Indication d'alignement

EBP76 · flexible
Sealed Vb (Qtc ≈ 0.71)≈ 64.5 L

EBP 50-100 : fonctionne en clos ou en bass-reflex.

Rules of thumb from T/S parameters only. Verify against a real simulation before cutting wood.

Candidats de substitution

HPFs (Hz)QtsVas (L)Xmax (mm)Sens (dB)AdéquationNotesComparer
Magnat XPRESS 150026 +10.312 =255 -167.9 -0.797.6 +0.3close300 W vs 380 W: lower power handling · Xmax 7.9 mm < 8.6 mm: lower excursion-limited SPL+
RCF L 15P200/A29 +40.291 -0.02280 +98.9 +0.396.6 -0.7close8 Ω vs 4 Ω: amp load changes · 300 W vs 380 W: lower power handling+
PHL Audio 5510MNds30 +50.324 +0.01293 +228.7 +0.196.6 -0.7close8 Ω vs 4 Ω: amp load changes+
RCF L 15P200 v198329 +40.291 -0.02280 +97.4 -1.296.6 -0.7close8 Ω vs 4 Ω: amp load changes · 300 W vs 380 W: lower power handling · Xmax 7.4 mm < 8.6 mm: lower excursion-limited SPL+
Monacor SPH-390TC vp24 -10.325 +0.02297 +266.2 -2.496.2 -1.1usable150 W vs 380 W: lower power handling · Xmax 6.2 mm < 8.6 mm: lower excursion-limited SPL+
Davis 39GCA15 v202426.3 +1.30.333 +0.02347 +767.5 -1.196.6 -0.7usable8 Ω vs 4 Ω: amp load changes · 300 W vs 380 W: lower power handling · Xmax 7.5 mm < 8.6 mm: lower excursion-limited SPL+
Dayton Audio APOLLO 15LF25.5 +0.50.26 -0.05331 +609.3 +0.796 -1.3usable8 Ω vs 4 Ω: amp load changes+
Dayton Audio 15LF ODEUM25.5 +0.50.26 -0.05331.3 +60.39.3 +0.796 -1.3usable8 Ω vs 4 Ω: amp load changes+
Beyma SM115/K29 +40.249 -0.06273 +28 -0.697.2 -0.1usable8 Ω vs 4 Ω: amp load changes · Xmax 8 mm < 8.6 mm: lower excursion-limited SPL+
Focal 38VX22.3 -2.70.279 -0.03347 +768.2 -0.496.9 -0.4usable225 W vs 380 W: lower power handling · Xmax 8.2 mm < 8.6 mm: lower excursion-limited SPL+

Comparer les 3 plus proches avec le SUPREME 3800 →

Classé par similarité de paramètres uniquement (Qts, Fs, Vas, Xmax, sensibilité). Même taille nominale requise. Une indication, pas une simulation, modélisez l'échange avant de couper ou d'acheter.

Utilisé dans les caissons (0)

No enclosure in the catalog uses this driver yet.